Seasonal and diurnal variations of volatile organic compounds (VOCs) in the atmosphere of Hong Kong.

نویسندگان

  • K F Ho
  • S C Lee
  • H Guo
  • W Y Tsai
چکیده

Ambient VOCs samples were collected at three locations (PolyU campus (PU), Kwun Tong (KT), Hok Tsui (HT)) in Hong Kong during the periods of November 2000-February 2001 and June 2001-August 2001. Also the concentrations of VOCs in Cross Harbor tunnel in Hong Kong were obtained in order to determine the vehicular sources of VOCs. Toluene was the most abundant VOC detected in Hong Kong. At the PU station, which is close to a main road, the concentrations of most VOCs were higher in summer than in winter. However, at the background location HT, the concentrations of all VOCs except tetrachloroethene were higher in winter than in summer. Regional physical dispersion/transportation and mixing depth may be the reasons for higher VOC concentrations in winter at HT. The BTEX (benzene:toluene:ethylbenzene:xylene) ratios of PU and KT during winter period were (1.9:10.1:1.0:1.8) and (1.9:10.4:1.0:1.5), and (0.9:8.3:1.0:2.2) and (0.8:29.6:1.0:1.8) for summer season, respectively. The xylene/ethylbenzene (X/E) ratio was used to assess the relative age of the air parcels in this study. The concentrations of VOCs in the atmosphere in Hong Kong were mainly affected by direct emissions from vehicles, evaporation of fuels, photochemical reactions and few industrial emissions. The BTEX ratio in the tunnel was 2:10.4:1:3.2. The BTEX ratios at PU and KT during the winter period were similar to that in tunnel (except for xylenes). The X/E ratio in the tunnel was higher than that in the ambient air. This indicated that the freshly emitted xylenes in the tunnel decayed at different rates from OH-oxidation in the atmosphere. Good BTEX correlations (r>0.8) were found at PU and KT in winter (**P<0.01). Vehicular exhaust was the dominant source at PU and KT stations, and less evaporation of fuel or additive occurred at low temperature in winter. Diurnal variations of mean BTEX concentrations at the roadside monitoring station (PU) showed two peaks associated with traffic density and vehicle type.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

C1–C8 volatile organic compounds in the atmosphere of Hong Kong: Overview of atmospheric processing and source apportionment

We present measurements of C1–C8 volatile organic compounds (VOCs) at four sites ranging from urban to rural areas in Hong Kong from September 2002 to August 2003. A total of 248 ambient VOC samples were collected. As expected, the urban and sub-urban sites generally gave relatively high VOC levels. In contrast, the average VOC levels were the lowest in the rural area. In general, higher mixing...

متن کامل

Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review

Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...

متن کامل

Habitation of volatile organic compounds (VOCs) in the aura of Agra the city of Taj Mahal

When speaking about harm to the human body in the term of pollution, indoor pollution is equally harmful as the outdoor pollution. Volatile Organic Compounds contribute to the toxic oxidants which are harmful to the ecosystem, human health and atmosphere. Volatile organic compounds (VOCs) are major group of air pollutants which play critical role in atmospheric chemistry. It contributes to toxi...

متن کامل

Oxidative capacity and radical chemistry in the polluted atmosphere of Hong Kong and Pearl River Delta region: analysis of a severe photochemical smog episode

15 We analyze a photochemical smog episode to understand the oxidative capacity and radical chemistry of the polluted atmosphere in Hong Kong and the Pearl River Delta (PRD) region. A photochemical box model based on the Master Chemical Mechanism (MCM v3.2) is constrained by an intensive set of field observations to elucidate the budgets of ROX (ROX=OH+HO2+RO2) and NO3 radicals. Highly abundant...

متن کامل

Seasonal, diurnal and nocturnal variations of carbonyl compounds in the semi-urban environment of Orléans, France.

Atmospheric carbonyls were measured at a semi-urban site in Orléans, France, from October 2010 to July 2011. Formaldehyde, acetaldehyde and acetone were found to be the most abundant carbonyls, with average concentrations of 3.1, 1.0, 2.0 ppb, respectively in summer, 2.3, 0.7, 2.2 ppb, respectively in autumn, 2.2, 1.0, 2.1 ppb, respectively in spring, and 1.5, 0.7, 1.1 ppb, respectively in wint...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Science of the total environment

دوره 322 1-3  شماره 

صفحات  -

تاریخ انتشار 2004