Seven human immunodeficiency virus (HIV) antigen-antibody combination assays: evaluation of HIV seroconversion sensitivity and subtype detection.
نویسندگان
چکیده
In this study, we evaluated the performance of two prototype human immunodeficiency virus (HIV) antigen-antibody (Ag-Ab) combination assays, one from Abbott Laboratories (AxSYM HIV Ag-Ab) and the other from bioMerieux (VIDAS HIV Duo Ultra), versus five combination assays commercially available in Europe. The assays were Enzygnost HIV Integral, Genscreen Plus HIV Ag-Ab, Murex HIV Ag-Ab Combination, VIDAS HIV Duo, and Vironostika HIV Uniform II Ag-Ab. All assays were evaluated for the ability to detect p24 antigen from HIV-1 groups M and O, antibody-positive plasma samples from HIV-1 groups M and O, HIV-2, and 19 HIV seroconversion panels. Results indicate that although all combination assays can detect antibodies to HIV-1, group M, subtypes A to G, circulating recombinant form (CRF) A/E, and HIV-1 group O, their sensitivity varied considerably when tested using diluted HIV-1 group O and HIV-2 antibody-positive samples. Among combination assays, the AxSYM, Murex, and VIDAS HIV Duo Ultra assays exhibited the best antigen sensitivity (at approximately 25 pg of HIV Ag/ml) for detection of HIV-1 group M, subtypes A to G and CRF A/E, and HIV-1 group O isolates. However, the VIDAS HIV Duo Ultra assay had a lower sensitivity for HIV-1 group M and subtype C, and was unable to detect subtype C antigen even at 125 pg of HIV Ag/ml. The HIV antigen sensitivity of the VIDAS HIV Duo and Genscreen Plus combination assays was approximately 125 pg of HIV Ag/ml for detection of all HIV-1 group M isolates except HIV-1 group O while the sensitivity of Vironostika HIV Uniform II Ag-Ab and Enzygnost HIV Integral Ag-Ab assays for all the group M subtypes was >125 pg of HIV Ag/ml. Among the combination assays, the AxSYM assay had the best performance for detection of early seroconversion samples, followed by the Murex and VIDAS HIV Duo Ultra assays.
منابع مشابه
Multicenter evaluation of a new, automated enzyme-linked immunoassay for detection of human immunodeficiency virus-specific antibodies and antigen.
A collaborative multicenter study was conducted to evaluate the sensitivity, specificity, and precision of a three-step, fully automated, qualitative microparticle-based enzyme-linked immunoassay (AxSYM HIV Ag/Ab Combo; Abbott Laboratories), designed to simultaneously detect (i). antibodies against human immunodeficiency virus type 1 (HIV-1) and/or type 2 (HIV-2) and (ii). HIV p24 antigen. A si...
متن کاملMulticenter evaluation of a new automated fourth-generation human immunodeficiency virus screening assay with a sensitive antigen detection module and high specificity.
Fourth-generation assays for the simultaneous detection of human immunodeficiency virus (HIV) antigen and antibody that were available on the international market until now have antigen detection modules with relatively poor sensitivity and produce a higher rate of false-positive results than third-generation enzyme immunoassays (EIAs). The new Cobas Core HIV Combi EIA with an improved sensitiv...
متن کاملQuantification Analysis of Dot Blot Assays for Human Immunodeficiency Virus Type 1 and 2 Antibodies
Objective Dot Blot (DB) assay provides highly specific results, but usually not reliable for quantification of antibody production. The need for a more objective DB assay to provide a better definition of the immune status, against HIV antigens, promoted this study to be done to develop a quantitative DB assay. Material and Methods Dot blot (DB) strips for antibodies directed to human immuno...
متن کاملEvaluation of a New Anti-HIV1/2 ELISA–HIV 1/2 REC Diagnostic Kit Based on E. coli Derived Soluble Recombinant Proteins: Ex-perience of an International Study
Background/Objective: Development of a new enzyme-linked immunosorbent assay (ELISA) for screening human blood serum and plasma for antibodies to human immunodeficiency virus type 1 (HIV1) and type 2 (HIV2) as HIV1/2REC ELISA diagnostic kit based on E. coli derived soluble recombinant proteins. Methods: Polypeptides corresponding to HIV1 gp41 and HIV2 gp36 immunodominant regions and HIV1 gag we...
متن کاملEvaluation of the siemens HIV antigen-antibody immunoassay.
Fourth-generation assays for the simultaneous detection of human immunodeficiency virus (HIV) antigen and antibodies are available on the international market and are currently used for blood donor screening and for HIV diagnosis. In this study we evaluated the performance of the novel automated fourth-generation ADVIA Centaur® HIV Ag/Ab Combo assay. The assay detected seroconversion at the sam...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 40 11 شماره
صفحات -
تاریخ انتشار 2001