Ectopic positioning of pacemaker electrode.
نویسندگان
چکیده
The present case reports on a patient presenting the cardiac form of Chagas disease, with left ventricular dysfunction and second-degree atrioventricular block Mobitz type II, associated with several syncope episodes. The patient underwent a double-chamber definitive artificial pacemaker implant. One year after the implant, the displacement of the atrial electrode was diagnosed and the patient was submitted to re-implantation of the atrial electrode. Two years after the first surgical procedure, the patient presented dyspnea on exertion. The physical evaluation included an echocardiogram, which detected the presence of a foreign body with metallic characteristics in the left cardiac chambers, consistent with that of an ectopic pacemaker electrode.
منابع مشابه
How Genetic Algorithms Can Improve a Pacemaker Effciency
In this paper, we propose the use of Genetic Algorithms as a tool for improving a pacemaker efficiency in a defective heart. Such device is generally used when the electrical activity of the heart is deficient and consists in applying electrodes on several points at the surface of the heart. By optimizing the positions of these electrodes with respect to a well chosen criteria, we show the sign...
متن کاملEarly Malfunction of Transvenous Pacemaker Electrodes
A 3-year study by three medical centers has revealed a 1-year electrode malfunction rate of 7.4%; most malfunctions occurred within the first 30 days. The incidence of unavoidable early malfunction (3.2%) fell within the 5% standards suggested by the committee report of the Inter-Society Committee on Heart Diseases. Incidences of obscure cause (3.2%) may be difficult to identify prospectively a...
متن کاملThe Subcutaneous Implantable Cardioverter- Defibrillator as Part of Dual Device Therapy in Complex Congenital Heart Disease
We report the case of a 44-year-old with unrepaired complex congenital heart disease (CHD), a pre-existing permanent pacemaker, and a subcutaneous implantable cardioverterdefibrillator (SICD) implanted for secondary prevention. Right parasternal electrode positioning and step-down defibrillation testing were integrated. Application of the SICD for device therapy in CHD patients remains quite li...
متن کاملAnodal stimulation as a cause of pacemaker-induced ventricular fibrillation.
T he possibility of pacemaker-induced ventricular arrhythmias has been recognized since the beginning of widespread use of artificial pacemakers,*-I6 but the extent of the clinical risk of such arrhythmias has been questionable.17-2* The possibility of a dangerous arrhythmia being precipitated by a pacemaker stimulus falling during the vulnerable period of a preceding ventricular beat exists mo...
متن کاملCatheter ablation techniques in patients with supraventricular tachycardia.
Catheter ablation is an experimental procedure that may prove useful for patients with drug-refractory supraventricular tachycardia. Current techniques involve the use of high-energy direct-current shocks, delivered via electrode catheters. These techniques have been used most commonly for ablating the atrioventricular (AV) junction in patients with supraventricular tachycardia. Such ablation m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arquivos brasileiros de cardiologia
دوره 94 5 شماره
صفحات -
تاریخ انتشار 2010