A coincidence scintillation spectrometer
نویسنده
چکیده
The coincidence spectrometer consists of two scintillation spectrometers, each of which can be used as either a beta-ray or a gamma-ray spectrometer, depending on what crystals are used. The pulses from the first spectrometer are analyzed with a single channel analyzer. The pulses corresponding to a certain energy are picked out with the analyzer and are fed into one channel of a coincidence circuit. The pulses from the second spectrometer are fed into the other channel of the circuit. The coincidence output pulses are used to trigger an oscilloscope. The pulses from the second spectrometer are displayed on the screen of the scope. Because the scope is triggered by the coincidence circuit, only those pulses from the second spectrometer which are in coincidence with the selected pulses from the first spectrometer are seen. The pulse distribution of the displayed pulses is recorded by photographic methods. Gamma-ray spectra are recorded by taking still pictures of the screen. Beta-ray spectra are recorded by photographing the screen with a movie camera, s~ that each individual pulse is recorded separately.
منابع مشابه
A beta-ray spectrometer for coincidence measurements
An intermediate image beta-ray spectrometer has been constructed utilizing the focusing properties of a Ushaped magnetic field distribution. The construction and performance of the instrument are discussed. A transmission of ten percent has been attained with a resolution of about six percent. A scintillation spectrometer is used in conjunction with the intermediate image spectrometer for the p...
متن کاملDetermination of chemical and radiochemical purity of [14C] clozapine by high performance liquid chromatography and liquid scintillation [Persian]
Introduction: The mechanism of action and metabolism of clozapine, a complex drug used in psychopharmacology, is not completely understood. The effects of this compound in human body are related to some interactions with serotonin and dopamine neurotransmitter receptors. To further elucidate the mechanism of action and to support ongoing drug metabolism studies, [14C] clozapine with suita...
متن کاملEfficiency of 47T-Crystal-Scintillation Counting: 1. Experimental Technique and Results
The technique of 47r-crystal-scintillation counting has been applied to the s tandardization of beta-emit t ing nuclides. Phototubes viewing an anthracene sandwiched source a t 180° have been used with high-gain nonoverloading amplifiers in addition and in coincidence circuits to obtain high detection efficiencies. A precise shorted delay-line coincidence analyzer is described. The results of m...
متن کاملMeasuring Electron Response in NaI(Tl) using Compton Coincidence Technique
The scintillation efficiency of electron recoils in liquid xenon (LXe) is not well measured at low energies. The Compton coincidence technique (CCT) is set up using a NaI(Tl) detector and HPGe detector to measure the energy dependence of the light yield in the NaI(Tl) detector from which we can extract the scintillation effieciency. This technique allows for the detection of low energy electron...
متن کاملEvaluation of Cerium Doped Lutetium Oxyorthosilicate ( LSO ) Scintillation Crystal for PET
A new scintillation crystal, cerium-doped lutetium oxyorthosilicate &SO) was recently discovered a, with light intensity 75 % of NaI(Tl), scintillation decay time of 12 ns (30%) and 42 ns (70%), effective Z of 66, and density of 7.4 glcc. The fast decay time and scintillation light output of LSO are superior to those of BGO for PET and the stopping power of LSO for 511 keV photons is only sligh...
متن کامل