On the Necessity of Traffic Shaping for PMU Measurement Data Streams

نویسندگان

  • Miroslav Popovic
  • Peng Gao
  • Dan-Cristian Tomozei
  • Jean-Yves Le Boudec
چکیده

We study the communication network of an on-campus active distribution network (ADN) that comprises phasor measurement units (PMUs) connected to medium-voltage transformers. Within stringent time delays and with minimal loss the PMUs periodically transfer fresh measurements through a phasor data concentrator (PDC) to a centralized electrical network state estimator (control point). Due to strict operational constraints, a dedicated robust communication infrastructure that withstands power shortages is needed. We use DSL technology (SHDSL) over existing telephone cables. We investigate the operating region of the system. In our experimental setup, we measure the achieved goodput (application layer throughput) for various measurement frequencies and frame sizes. We observe that goodput drops catastrophically, in some scenarios for which the PDC data transmission rate slightly exceeds the capacity of the SHDSL link for a short period of time. Specifically, when the offered traffic exceeds channel capacity by 20%, we observe up to 90% of lost packets. We explain this surprising phenomenon by the combination of IP fragmentation that splits each frame in two IP packets of significantly different sizes and the FIFO/tail-drop queuing discipline implemented within line terminal devices at the source end. We conclude that the guidelines of the C37.118.2-2011 standard are not sufficient for designing a PMU data transfer layer. Implementing traffic shaping within PMUs is essential for avoiding excessive packet losses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Data Driven Framework for Real Time Power System Event Detection and Visualization

Increased adoption and deployment of phasor measurement units (PMU) has provided valuable fine-grained data over the grid. Analysis over these data can provide real-time insight into the health of the grid, thereby improving control over operations. Realizing this data-driven control, however, requires validating, processing and storing massive amounts of PMU data. This paper describes a PMU da...

متن کامل

The Health Policy Process in Vietnam: Going Beyond Kingdon’s Multiple Streams Theory; Comment on “Shaping the Health Policy Agenda: The Case of Safe Motherhood Policy in Vietnam”

This commentary reflects upon the article along three broad lines. It reflects on the theoretical choices and omissions, particularly highlighting why it is important to adapt the multiple streams framework (MSF) when applying it in a socio-political context like Vietnam’s. The commentary also reflects upon the analytical threads tackled by Ha et al; for instance, it highlights the opportunitie...

متن کامل

Online Inertia Constant and Thévenin Equivalent Estimation Using PMU Data

In this paper a new algorithm based on phasor measurements for estimating the Thévenin Equivalent (TE) and system inertia constant is proposed. The method estimates the network TE seen from a generator terminal and equivalent system inertia constant by means of phasor data that is available at Phasor Data Concentrator (PDC) center. It is shown that the parameters of the TE could be estimated at...

متن کامل

A Model For The Residence Time Distribution and Holdup Measurement in a Two Impinging Streams Cyclone Reactor/Contactor in Solid-Liquid Systems

In this paper a two impinging streams cyclone contacting system suitable for handling of solid-liquid systems has been studied. Certain pertinent parameters such as: solid holdup, mean residence time and Residence Time Distribution (RTD) of solid particles have been investigated. A stochastic model based on Markov chains processes has been applied which describe the behavior of solid partic...

متن کامل

Observability-Enhanced PMU Placement Considering Conventional Measurements and Contingencies

Phasor Measurement Units (PMUs) are in growing attention in recent power systems because of their paramount abilities in state estimation. PMUs are placed in existing power systems where there are already installed conventional measurements, which can be helpful if they are considered in PMU optimal placement. In this paper, a method is proposed for optimal placement of PMUs incorporating conve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013