Ultrasound-Guided Radial Artery Compression to Assess Blood Pressure
نویسندگان
چکیده
INTRODUCTION We proposed using compression sonography to observe the coaptation and collapse of the radial artery as a surrogate for automated cuff blood pressures (BP). We hypothesize that the pressure required to achieve coaptation and complete collapse of the artery would correlate to the diastolic and systolic BP, respectively. This pilot study was to assess the feasibility of ultrasound-guided radial artery compression (URAC) for BP measurement and compare patient comfort levels during automated cuff with URAC measurements. METHODS This was a prospective cohort pilot study with a convenience sampling of 25 adult patients at a single urban emergency department. URAC pressure was measured, followed by cuff manometry on the same arm. A 100mL normal saline bag was connected to the Stryker pressure monitor and placed on the volar wrist. Pressure was applied to the bag with a linear transducer and the radial artery was observed for coaptation of the anterior and posterior walls and complete collapse. Pressures required for coaptation and collapse were recorded from the Stryker display. Patient level of comfort was also documented during the URAC method, with patients reporting either "more," "same" or "less" comfort in comparison to automated cuffs. We analyzed data using intraclass correlation and paired t-tests. Interrater reliability was calculated using intraclass correlation. RESULTS The mean cuff systolic BP was 138.6 ± 22.1 mmHg compared to 126.9 ± 19.8 mmHg for the URAC systolic BP (p=0.02). For diastolic BP, there was no significant difference between the cuff BP and the URAC BP (83.7 ± 13.0 cuff vs. 86.5 ± 19.8 URAC, p=0.46). The intraclass correlation (ICC) for systolic BP was 0.48 (p=0.04) and 0.57 (p=0.02) for diastolic BP. The agreement between the two observers was 0.88 for identifying coaptation on ultrasound (diastolic pressure) and was 0.92 for identifying collapse (systolic pressure). Eighty percent (20/25) of subjects found the URAC method more comfortable than the cuff measurement, and the remainder found it the same (5/20). CONCLUSION This pilot study showed statistically significant moderate correlation between automated cuff diastolic BP and URAC measurements for vessel coaptation. Additionally, most patients found the URAC method more comfortable than traditional cuff measurements. Compression ultrasonography shows promise as an alternative method of BP measurement, though future studies are needed.
منابع مشابه
Review of Ultrasound-Guided Radial Artery Catheter Placement.
Radial artery catheters are commonly placed for continuous blood pressure monitoring, frequent arterial blood gas analysis, or frequent blood sampling for diagnostic testing. Radial artery cannulation can be challenging and ultrasound guidance has emerged as a valuable adjunct for the placement of radial artery catheters. The advantages of ultrasound guidance include: real-time visualization of...
متن کاملArterial Pseudoaneurysm in Neonates with Hemophilia: Successful Treatment with Noninvasive Clotting Factor Replacement and Ultrasound-guided Compression
Vascular cannulation is an invasive procedure that carries the risk of complications such as pseudoaneurysms. Hemophilia, the most common severe bleeding disorder of inheritance, increases the risk of such complications through underlying hypocoagulability. Although surgical ligation has been considered the gold standard treatment, less invasive options are currently available. Here we present ...
متن کاملAnalysis of radial artery catheter placement by respiratory therapists using ultrasound guidance.
BACKGROUND The use of ultrasound (US) guidance for radial artery cannulation has been shown to improve first attempt success rate, reduce time to successful cannulation, and reduce complications. We sought to determine whether properly trained respiratory therapists (RTs) could utilize US guidance for the placement of radial artery catheters. Primary outcome measurements were successful cannula...
متن کاملEvaluating the effect of stenosis increase and pulsatile blood pressure on effective stress distribution in viscoelastic finite element model based on carotid artery ultrasound images
The aim of this study is to evaluate the changes of effective stress distribution in plaque by progressing to the stenosis throat and to assess the pulsatile pulse pressure effect on effective stress of a viscoelastic finite-element model of carotid arteries having less and more than 50% stenosis. In-vivo geometries of the arteries were reconstructed using consecutive transverse ultrasound imag...
متن کاملManagement of an iatrogenic radial artery perforation: a case report.
A 73-year-old female patient underwent transradial coronary angiography with stable angina and signs of significant myocardial ischemia revealed by exercise stress test. After insertion of a 6F radial sheath into the right radial artery and intra-arterial administration of heparin plus verapamil, the hydrophilic guidewire could not be advanced under fluoroscopic guidance. Immediately afterwards...
متن کامل