Feasibility and limitations of acridine orange fluorescence technique using a Malaria Diagnosis Microscope in Myanmar.

نویسندگان

  • Ye Htut
  • Kyin Hla Aye
  • Kay Thwe Han
  • Myat Phone Kyaw
  • Kunio Shimono
  • Shigeru Okada
چکیده

We studied parasite detectability in thick films by an acridine orange fluorescence technique (AO) to test its applicability and the use of a Malaria Diagnosis Microscope (MDM)-ESL in the detection of parasites, compared to the conventional Giemsa staining method. This study was conducted on 1,390 clinically suspected malaria cases of Thaton township, Myanmar. We found sensitivities of 82.8% for Plasmodium falciparum (P. falciparum) and 100% for Plasmodium vivax (P. vivax) and specificities of 97.1% for P. falciparum and 98.6% for P. vivax. AO had a higher sensitivity than Giemsa-stained films at low levels of parasitemia (< 1,000/microl). AO showed lower sensitivity and higher specificity than the Giemsa method at parasite levels of more than 1,000/microl. The results of using the AO method, achieved by both novice and experienced observers, showed no significant difference and required less practice to perform the test as well as to identify the parasite. The acridine orange fluorescence technique using a malaria diagnosis microscope MDM-ESL series is simple, rapid and cost effective. The microscope is conveniently operable using standard AC power or a 12-V DC car battery, and it is easily convertible to a conventional biological microscope. With the exception of species differentiation, which is not possible with this method, this method would be appropriate for both clinical and epidemiological studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid diagnosis of malaria by fluorescence microscopy with light microscope and interference filter.

Fluorochrome staining to detect malaria parasites in bloodfilms is more sensitive, is easier to do, and is less time-consuming than Giemsa staining. However, standard epi-illuminated, mercury vapour, fluorescence microscopes are expensive, especially for tropical countries where malaria is endemic. Fluorescence microscopy with a standard light microscope and a new interference filter specially ...

متن کامل

Evaluation of different methods for diagnosis of P. falciparum malaria.

Rapid diagnosis is a prerequisite for institution of effective treatment and reducing the mortality and morbidity of falciparum malaria. This study was taken up to compare the efficacy of various rapid methods viz, acridine orange, Plasmodium falciparum histidine rich protein II antigen detection and Field's stain with traditional microscopy i.e, Leishman stain for diagnosing falciparum malaria...

متن کامل

Diagnosis of Malaria Infection using Three Diagnostic Techniques in Diary Villages Khartoum North State during the Period October 2015-Febrory 2016

Background: Laboratory diagnosis of malaria is currently recommended for the confirmation of the disease before management. The two most common techniques in use for the diagnosis of malaria parasite in Sudan are Giemsa stained smears and Rapid diagnostic tests(RDTs). This study was carried out to compare microscopy ( Giemsa and Acridine orange stain ) and RDTs as effective tools for the diagno...

متن کامل

Laboratory Diagnosis of Malaria

R apid and accurate diagnosis is a key to the success of an effective treatment of malaria. The global impact of malaria has spurred interest in developing diagnostic strategies that will be effective not only in resource-limited areas but also in developed countries, where expertise in malaria diagnosis is often lacking. Accurate diagnosis of malaria is necessary to prevent morbidity and morta...

متن کامل

An insight to optical studies of acridine orange cationic dye within nanometer-sized microemulsions at fixed water content

Cationic dye Acridine orange (AO) has wide applications especially in biologicalfields such as analysis of lysosomal and mitochondria content by flow cytometryand so on. In the current work, spectroscopy of acridine orange (AO) dye at bothlow concentrations (mdye/mwater=6.25×10-5, 3.12×10-5) and high concentrations(mdye/mwater=0.002, 0.001) was studied in confined water ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta medica Okayama

دوره 56 5  شماره 

صفحات  -

تاریخ انتشار 2002