Pulse-shape Discrimination for Identification of Neutron Sources Using the Bc-501a Liquid Scintillator

نویسندگان

  • M. Flaska
  • S. A. Pozzi
چکیده

Fast and accurate identification of neutron sources is very important in nuclear nonproliferation and international safeguards applications. Commonly, the identification of neutron spectra relies on unfolding procedures, which requires the solution of an ill-posed problem. In this paper, we present a new application of an existing technique, which can be used for neutron source identification without employing energy-spectrum unfolding techniques. This technique is based on the acquisition of measured neutron pulse-height spectra by using a liquid scintillation detector BC-501A and a fast waveform digitizer TDS-5104. The technique employs an optimized digital pulse-shape discrimination method based on the standard charge integration method to discriminate neutrons from gamma rays. The accuracy of the neutron-source identification method was tested on three neutron sources: californium-252 (Cf-252), americium-beryllium (Am-Be), and americium-lithium (Am-Li). Several source-shielding configurations were investigated to assess the influence of potential shielding of the source on the accuracy of the method. This aspect was addressed by using lead and polyethylene shielding blocks. The measured pulse-height distributions were compared with the distributions simulated with the MCNP-PoliMi code, and excellent agreement was obtained for the Cf-252 and the Am-Be sources. The agreement for the Am-Li source was less favorable due to the uncertainty of measured data. The final results show that for all tested source-shielding configurations, the identification of the Cf-252, Am-Be, and Am-Li sources by direct analysis of the measured pulse-height distributions is very straightforward, and no subsequent neutron energy-spectrum unfolding is required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A first comparison of the responses of a He-based fast-neutron detector and a NE-213 liquid-scintillator reference detector

A first comparison has been made between the pulse-shape discrimination characteristics of a novel He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between neu...

متن کامل

Digital pulse-shape discrimination of fast neutrons and γ rays

Discrimination of the detection of fast neutrons and γ rays in a liquid scintillator detector has been investigated using digital pulse-processing techniques. An experimental setup with a 252Cf source, a BC-501 liquid scintillator detector, and a BaF2 detector was used to collect waveforms with a 100 Ms/s, 14 bit sampling ADC. Three identical ADC’s were combined to increase the sampling frequen...

متن کامل

Digital pulse shape analysis for the capture-gated liquid scintillator BC-523A

The BC-523A detector is a boron-10-loaded liquid scintillation detector that is sensitive to not only fast neutrons and gamma rays, but also to thermal neutrons. This detector has recently attracted the attention of several researchers and has shown promise for neutron spectroscopy. Several efforts have been made to accurately characterize this detector for several neutron and gamma-ray energie...

متن کامل

PULSE SHAPE DISCRIMINATION CHARACTERISTICS OF STILBENE CRYSTAL, EJ-299-33 AND Li LOADED PLASTIC SCINTILLATORS FOR A HIGH RESOLUTION CODED-APERTURE NEUTRON IMAGER

Pulse shape discrimination performances of single stilbene crystal, EJ-299-33 plastic and Li loaded plastic scintillators have been compared. Pulse Gradient Analysis pulse shape discrimination algorithm has been tested for each scintillator sample, assessing their neutron/gamma separation. In this study each scintillator sample was irradiated with a Cf neutron source and, a real-time fast digit...

متن کامل

Neutron generator burst timing measured using a pulse shape discrimination plastic scintillator with silicon photomultiplier readout

An EJ-299-34 plastic scintillator with silicon photomultiplier (SiPM) readout was used to measure the fast neutron output of a pulsed Thermo-Fisher A-325 Deuterium-Tritium sealed tube neutron generator (STNG). The SiPM signals were handled by a prototype digital pulse processing system, based on a free-running analogue to digital converter feeding a digital signal processor (DSP). Pulse shape d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007