Analysis of Sternal Fixation Results According to Plate Type in Sternal Fracture

نویسندگان

  • Chun Sung Byun
  • Il Hwan Park
  • Wan Jin Hwang
  • Yeiwon Lee
  • Hyun Min Cho
چکیده

BACKGROUND Sternal fractures are relatively rare, and caused mainly by blunt anterior chest wall trauma. In most cases, sternal fractures are treated conservatively. However, if the patient exhibits problematic symptoms such as intractable chest wall pain or bony crepitus due to sternal instability, surgical correction is indicated. But no consensus exists regarding the most appropriate surgical method. We analyzed the results of surgical fixation in cases of sternal fracture in order to identify which surgical method led to the best outcomes. METHODS We retrospectively reviewed the medical records of patients with sternal fractures from December 2008 to December 2011, and found 19 patients who underwent open reduction and internal fixation of the sternum with a longitudinal plate (L-group) or a T-shaped plate (T-group). We investigated patients' characteristics, clinical details regarding each case of chest trauma, the presence of other associated injuries, the type of open reduction and fixation, whether a combined operation was performed, and postoperative complications. RESULTS Of the 19 patients, 10 patients (52.6%) were male, and their average age was 56.8 years (range, 32 to 82 years). Seven patients (36.8%) had isolated sternal fractures, while 12 (63.2%) had other associated injuries. Seven patients (36.8%) were in the L-group and 12 patients (63.2%) were in the T-group. Three patients in the L-group (42.9%) showed a loosening of the fixation. In all patients in the T-group, the fracture exhibited stable alignment. CONCLUSION Open reduction and internal fixation with a T-shaped plate in sternal fractures is a safer and more efficient treatment method than treatment with a longitudinal plate, especially in patients with a severely displaced sternum or anterior flail chest, than a longitudinal plate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Treatment of traumatic sternal fractures with titanium plate internal fixation: a retrospective study

BACKGROUND This study aim to evaluate surgical procedures for titanium plate internal fixation of sternal fractures with displacement or nonunion. METHODS From January 2010 to December 2014, 64 patients with sternal fractures were treated with titanium plate internal fixation in the thoracic surgery department of the Shanghai Sixth People's Hospital. Pain severity scale scores were analyzed p...

متن کامل

The laparoscopically harvested omental flap and transverse plate fixation for sternal reconstruction in complicated sternal wound infection after cardiac surgery

Methods Between 2010 and 2011, 6 patients with type IV deep sternal wound infection underwent a sternal reconstruction with a laparoscopically harvested omental flap and transverse plate fixation. The median age of the cohort (1 female and 5 males), was 72.5 years (range: 4978 years). In 5 patients, a bilateral internal thoracic artery had been used. Considerable preoperative risk factors were ...

متن کامل

Early Surgical Reconstruction of Sternum with Longitudinal Rigid Polymer Plating after Acute Chest Trauma.

PURPOSE The surgical management of the patients with traumatic sternal fractures remains controversial. The aim of this study was to evaluate the effectiveness of an early surgical reconstruction of a displaced sternal fracture utilizing longitudinal rigid polymer fixation in the settings of an acute chest trauma. METHODS To perform the sternal fixation, we utilized a longitudinal rigid plati...

متن کامل

Sternal reconstruction with titanium plates in complicated sternal dehiscence.

OBJECTIVE Sternal dehiscence after median sternotomy can be a challenging problem in case of multiple fractures or infection. The use of titanium plates is a promising approach for sternal reconstruction. METHODS Titanium plate fixation was used in 15 patients (67+/-5.9 years, 171+/-8.2 cm, 93.6+/-14.9 kg, body mass index 32+/-5 kg/m(2)) with unstable thorax after failed attempts of sternal c...

متن کامل

Sternal reentry in a patient with previous deep sternal wound infection managed with horizontal titanium plate fixation

Redo open-heart surgery and sternal reentry in patients with previous deep sternal wound infection (DSWI) and absence of sternal integrity can be a delicate and morbid task due the lack of a dissection plane between the heart and the surrounding soft tissues. Delayed sternal reconstruction and osteosynthesis with horizontal titanium plating fixation (Synthes) following vacuum assisted therapy (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 49  شماره 

صفحات  -

تاریخ انتشار 2016