Use of the forced-oscillation technique to estimate spirometry values

نویسندگان

  • Shoichiro Yamamoto
  • Seigo Miyoshi
  • Hitoshi Katayama
  • Mikio Okazaki
  • Hisayuki Shigematsu
  • Yoshifumi Sano
  • Minoru Matsubara
  • Naohiko Hamaguchi
  • Takafumi Okura
  • Jitsuo Higaki
چکیده

PURPOSE Spirometry is sometimes difficult to perform in elderly patients and in those with severe respiratory distress. The forced-oscillation technique (FOT) is a simple and noninvasive method of measuring respiratory impedance. The aim of this study was to determine if FOT data reflect spirometric indices. PATIENTS AND METHODS Patients underwent both FOT and spirometry procedures prior to inclusion in development (n=1,089) and validation (n=552) studies. Multivariate linear regression analysis was performed to identify FOT parameters predictive of vital capacity (VC), forced VC (FVC), and forced expiratory volume in 1 second (FEV1). A regression equation was used to calculate estimated VC, FVC, and FEV1. We then determined whether the estimated data reflected spirometric indices. Agreement between actual and estimated spirometry data was assessed by Bland-Altman analysis. RESULTS Significant correlations were observed between actual and estimated VC, FVC, and FEV1 values (all r>0.8 and P<0.001). These results were deemed robust by a separate validation study (all r>0.8 and P<0.001). Bias between the actual data and estimated data for VC, FVC, and FEV1 in the development study was 0.007 L (95% limits of agreement [LOA] 0.907 and -0.893 L), -0.064 L (95% LOA 0.843 and -0.971 L), and -0.039 L (95% LOA 0.735 and -0.814 L), respectively. On the other hand, bias between the actual data and estimated data for VC, FVC, and FEV1 in the validation study was -0.201 L (95% LOA 0.62 and -1.022 L), -0.262 L (95% LOA 0.582 and -1.106 L), and -0.174 L (95% LOA 0.576 and -0.923 L), respectively, suggesting that the estimated data in the validation study did not have high accuracy. CONCLUSION Further studies are needed to generate more accurate regression equations for spirometric indices based on FOT measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Using the forced oscillation technique to evaluate bronchodilator response in healthy volunteers and in asthma patients presenting a verified positive response.

OBJECTIVE To use the forced oscillation technique to evaluate asthma patients presenting positive bronchodilator responses (confirmed through spirometry) and compare the results with those obtained in healthy individuals. METHODS The study sample consisted of 53 non-smoking volunteers: 24 healthy subjects with no history of pulmonary disease and 29 asthmatics presenting positive bronchodilato...

متن کامل

Using the forced oscillation technique to evaluate respiratory resistance in individuals with silicosis.

OBJECTIVE To evaluate the resistance values obtained through the use of the forced oscillation technique in patients with varying degrees of airway obstruction resulting from silicosis. METHODS A total of 40 never-smoking volunteers were analyzed: 10 were healthy subjects with no history of pulmonary disease or silica exposure, and 30 had silicosis. The forced oscillation technique was used t...

متن کامل

The forced oscillation technique in clinical practice: methodology, recommendations and future developments.

The forced oscillation technique (FOT) is a noninvasive method with which to measure respiratory mechanics. FOT employs small-amplitude pressure oscillations superimposed on the normal breathing and therefore has the advantage over conventional lung function techniques that it does not require the performance of respiratory manoeuvres. The present European Respiratory Society Task Force Report ...

متن کامل

Forced oscillation technique in the detection of smoking‐induced respiratory alterations: diagnostic accuracy and comparison with spirometry

INTRODUCTION Detection of smoking effects is of utmost importance in the prevention of cigarette-induced chronic airway obstruction. The forced oscillation technique offers a simple and detailed approach to investigate the mechanical properties of the respiratory system. However, there have been no data concerning the use of the forced oscillation technique to evaluate respiratory mechanics in ...

متن کامل

Contrasting diagnosis performance of forced oscillation and spirometry in patients with rheumatoid arthritis and respiratory symptoms

OBJECTIVES Pulmonary involvement in rheumatoid arthritis is directly responsible for 10% to 20% of all mortality. The best way to improve the prognosis is early detection and treatment. The forced oscillation technique is easy to perform and offers a detailed exam, which may be helpful in the early detection of respiratory changes. This study was undertaken to (1) evaluate the clinical potentia...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017