Performance of an Improved TEM SDD Detector
نویسندگان
چکیده
External SDD systems can also replace Si(Li) detectors on existing microscopes and offer many of the advantages of the in-situ SDD systems. Since the SDDs do not operate at liquid nitrogen temperatures, the insulation gaps in the nosepiece/collimator assemblies can be reduced or eliminated. Also, the detector window and the associated support frame are no longer used. This means that the detecting area can be moved closer to the sample improving the solid angle for signal collection. In addition, the fact that the detector operates at -20C to -30C instead of cryogenic temperatures means that ice buildup on the detector is no longer an issue. One limitation to increasing the solid angle is that the detector must fit through the port in the sample stage area. While detectors are being made with larger and larger active areas, if they can’t fit through the microscope port they are useless.
منابع مشابه
A Double Silicon Drift Type Detector System for EDS with Ultrahigh Efficiency and Throughput for TEM
For elemental analysis with energy dispersive X-ray spectroscopy (EDS) in transmission electron microscopy (TEM), the demand for the improved efficiency of X-ray detection, a higher counting rate, is very strong, because the improvement not only results in high throughput, but also extends the method to the specimens fairly susceptible to electron beam damage. We have already developed and intr...
متن کاملCommissioning of the Silicon Drift Detectors of the ALICE experiment at the LHC
Silicon Drift Detectors (SDD) equip the two central layers of the Inner Tracking System of the ALICE experiment at the LHC. Main results of systematic studies of detector performance including noise, gain, drift speed and charge collection measurements will be reported. 1 ALICE experiment and SDD module Silicon Drift Detectors (SDD) [1] offer two-dimensional position reconstruction with a limit...
متن کاملA Comparison of Oxide Thickness Measurements of Uranium Dioxide and Tantalum Pentoxide Using Both User-Acquired and Built-In EDS Standards
In this work we describe thickness measurements from oxide layers on uranium and tantalum using Energy Dispersive Spectroscopy (EDS) combined with Oxford Instruments software calculating the layer thickness from measured X-ray intensities. A comparison of the oxide distribution is shown between (1) a user standardised system with an older SDD detector and INCA ThinFilmID and (2) the latest larg...
متن کاملElemental Analysis of Biological and Cryogenic Samples
Introduction Commercial production of large-area silicon drift detectors (SDDs) heralds an exciting new time in biological elemental analysis. Improved low-energy performance and higher collection efficiencies mean EDS is no longer limited by low count rates and poor solid angles. High count rates can be achieved on all types of materials, including soft biological tissues, without altering nor...
متن کاملSilicon Lithium Detectors for Synchrotron Energy Dispersive X-Ray Fluorescence Spectroscopy
Introduction Detector description and its principle of operation Detector module. Detector Features and its Performance EDXRF of Fe 55 Spectrum Detector comparison with Silicon Drift Detector SDD Concluding remarks References A Silicon Lithium Si(Li) detector is presented. The detector structure and its working principle are explained. The detector is cooled to 77o K by liquid Nitrogen. The det...