Improving measurement accuracy by optimum data acquisition for Nd:YAG Thomson scattering system.
نویسندگان
چکیده
A new high speed Nd:YAG Thomson scattering AD Convertor (HYADC) that can directly convert the detected scattered light signal into a digital signal is under development. The HYADC is expected to improve a signal to noise ratio of the Nd:YAG Thomson scattering measurement. The data storage of the HYADC which is required for the direct conversion of whole plasma discharge is drastically reduced by a ring buffer memory and a stop trigger system. Data transfer of the HYADC is performed by the SiTCP. The HYADC is easily expandable to a multi-channel system by the distributed data processing, and is very compact and easy to implement as a built-in system of the polychromators.
منابع مشابه
Diii – D Thomson Scattering Diagnostic Data Acquisition , Processing , and Analysis Software
One of the diagnostic systems critical to the success of the DIII–D tokamak experiment is the Thomson scattering diagnostic. This diagnostic is unique in that it measures local electron temperature and density: 1) at multiple locations within the tokamak plasma; and 2) at different times throughout the plasma duration. Thomson “raw” data are digitized signals of scattered light, measured at dif...
متن کاملEstimation of Plasma Light in Thomson Scattering System Designed for the COMPASS Tokamak
The COMPASS tokamak, originally from Culham laboratory, UKAEA, has been reinstalled at Institute of Plasma Physics, Prague. Many innovations will be done and new diagnostics have to be constructed. Electron temperature Te and density ne as key parameters of fusion plasma will be measured directly by the newly designed high spatial resolution incoherent Thomson scattering system. The scientific ...
متن کاملDesign of a new Nd:YAG Thomson scattering system for MAST.
A new infrared Thomson scattering system has been designed for the MAST tokamak. The system will measure at 120 spatial points with approximately 10 mm resolution across the plasma. Eight 30 Hz 1.6 J Nd:YAG lasers will be combined to produce a sampling rate of 240 Hz. The lasers will follow separate parallel beam paths to the MAST vessel. Scattered light will be collected at approximately f/6 o...
متن کاملDesign of Filters for COMPASS Thomson Scattering Diagnostics
Reinstalled tokamak COMPASS, originally from Culham Science Centre, is now operating at the Institute of Plasma Physics, Prague and many new optical diagnostics are being developed [Sestak et al, 2009]. For measurement of electron temperature and density profiles, high resolution incoherent Thomson scattering spectroscopy based on Nd:YAG laser and avalanche photodiodes is under development now....
متن کاملUpgraded Calibrations of the Thomson System at Diii-d
The DIII–D Thomson system measures electron density and temperature with eight pulsed ND:YAG lasers along three paths through the plasma vessel. The components of the Thomson system are absolutely calibrated so the measurements can be combined into a single profile from a normalized plasma radius (p) of about 0.1 to the edge of the plasma. A monochromator calibration and opto-electronic calibra...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Review of scientific instruments
دوره 85 11 شماره
صفحات -
تاریخ انتشار 2014