Theoretical and numerical studies of coupling multizone and CFD models for building air distribution simulations.

نویسندگان

  • L Wang
  • Q Chen
چکیده

UNLABELLED Multizone network models employ several assumptions, such as uniform temperature and pressure and quiescent air inside a zone, which may lead to inaccurate results in flow calculations. These assumptions can be eliminated in the zones, where the assumptions are inappropriate, by coupling a multizone network program with a computational fluid dynamics (CFD) program. Through theoretical analysis, this paper proves that the solution of air distribution by using the coupled program exists and is unique. Three possible coupling methods have been discussed in the paper. The best method is pressure-pressure coupling that exchanges pressure between the multizone and CFD because it is most stable and can always lead to a converged solution. Numerical tests were further performed to verify the theory and it demonstrated that the coupled program is able to effectively improve the accuracy of the results. PRACTICAL IMPLICATIONS The results of this paper provide a theoretical basis for improving the accuracy for modeling airflow and contaminant distributions in buildings. The coupled multizone and computational fluid dynamics can give high fidelity results, so field measurements may not be needed in the future. Designers of indoor environment in the future can use such a tool to evaluate different alternatives in design and identify the best solution for a building that can provide a healthy indoor environment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

On-Site Experimental Validation of a Coupled Multizone and CFD Model for Building Contaminant Transport Simulations

Previous studies indicated that the coupling of multizone and CFD (Computational Fluid Dynamics) models can provide a good compromise between the accuracy and required computation time. The results show that the coupled model predicts contaminant distribution more accurately than multizone model alone for the zones close to the contaminant source location. For all other zones, the multizone mod...

متن کامل

Validation of a Coupled Multizone and CFD Program for Building Airflow and Contaminant Transport Simulations

Current multizone airflow network models assume air momentum effects, contaminant concentrations and air temperatures are uniformly and homogeneously distributed in a zone of a building. These assumptions can cause errors for zones where air and/or contaminant are not well mixed. A coupled multizone-CFD program has been developed to improve the multizone model by applying a CFD model to those p...

متن کامل

Ventilation performance prediction for buildings: A method overview and recent applications

This paper presented an overview of the tools used to predict ventilation performance in buildings. The tools reviewed were analytical models, empirical models, small-scale experimental models, full-scale experimental models, multizone network models, zonal models, and Computational Fluid Dynamics (CFD) models. This review found that the analytical and empirical models had made minimal contribu...

متن کامل

Geometrical and Topological Issues for Coupling Dimensionally Reduced Multizone Models with High-resolution Cfd Techniques

In this paper we emphasize a technique based on graph theory that allows for deriving both a dimensionally reduced object model required for setting up a thermal multizone model and a geometrical model for defining a single or multiple CFD domains in a building model together with incidence matrices correlating these models. The incidence matrices are an essential precondition for establishing ...

متن کامل

Natural Ventilation: Analysis of Indoor Airflow in an Assumed Cubic Building with Opposite Openings by CFD Investigations

The natural ventilation is an easy way to exchange the indoor polluted warm air with outdoor fresh air. The wind power injects outdoor fresh air into the building. A good indoor air current and subsequently a proper exhaust depend on the openings’ conditions and their situations. A serious architectural question is under what conditions of the openings the wind-cross ventilation can be effectiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Indoor air

دوره 17 5  شماره 

صفحات  -