Dried blood spot HIV-1 RNA quantification: A useful tool for viral load monitoring among HIV-infected individuals in India

نویسندگان

  • Ujjwal Neogi
  • Soham Gupta
  • Rashmi Rodridges
  • Pravat Nalini Sahoo
  • Shwetha D. Rao
  • Bharat B. Rewari
  • Suresh Shastri
  • Ayesha De Costa
  • Anita Shet
چکیده

BACKGROUND & OBJECTIVES Monitoring of HIV-infected individuals on antiretroviral treatment (ART) ideally requires periodic viral load measurements to ascertain adequate response to treatment. While plasma viral load monitoring is widely available in high-income settings, it is rarely used in resource-limited regions because of high cost and need for sophisticated sample transport. Dried blood spot (DBS) as source specimens for viral load measurement has shown promise as an alternative to plasma specimens and is likely to be a useful tool for Indian settings. The present study was undertaken to investigate the performance of DBS in HIV-1 RNA quantification against the standard plasma viral load assay. METHODS Between April-June 2011, 130 samples were collected from HIV-1-infected (n=125) and non-infected (n=5) individuals in two district clinics in southern India. HIV-1 RNA quantification was performed from DBS and plasma using Abbott m2000rt system after manual RNA extraction. Statistical analysis included correlation, regression and Bland-Altman analysis. RESULTS The sensitivity of DBS viral load was 97 per cent with viral loads >3.0 log 10 copies/ml. Measurable viral load (>3.0 log 10 copies/ml) results obtained for the 74 paired plasma-DBS samples showed positive correlation between both the assays (r=0.96). For clinically acceptable viral load threshold values of >5,000 copies/ml, Bland-Altman plots showed acceptable limits of agreement (-0.21 to +0.8 log 10 copies/ml). The mean difference was 0.29 log 10 copies/ml. The cost of DBS was $2.67 lower compared to conventional plasma viral load measurement in the setting. INTERPRETATION & CONCLUSIONS The significant positive correlation with standard plasma-based assay and lower cost of DBS viral load monitoring suggest that DBS sampling can be a feasible and economical means of viral load monitoring in HIV-infected individual in India and in other resource-limited settings globally.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of HTLV-I proviral load, HIV viral load and CD4 T cell count in infected subjects; with an emphasis on viral replication in co-infection

  Objective(s): HTLV-I and HIV virus quantification is an important marker for assessment of virus activities. Since there is a direct relationship between the number of virus and disease progression, HTLV- I and HIV co-infection might have an influence on the development of viral associated diseases, thus, viral replication of these viruses and co-infection were evaluated.   Materials and...

متن کامل

Determination of HIV-1 viral load on dried blood spot specimens

Dried blood spot specimens on filter paper were evaluated to determine the viral load of the human immunodeficiency virus type 1 (HIV-1), through the Cobas®Ampliprep/Cobas®Taqman® HIV-1 test. RNA levels were quantified in pairs of plasma and dry blood spot specimens on filter paper from persons infected with HIV-1. The Pearson linear correlation coefficient was calculated as well as the agreeme...

متن کامل

Measurement of viral load by the automated Abbott real-time HIV-1 assay using dried blood spots collected and processed in Malawi and Mozambique.

BACKGROUND The use of dried blood spots (DBS) for HIV-1 viral load quantification can greatly improve access to viral monitoring for HIV-infected patients receiving treatment in resource-limited settings. OBJECTIVES To evaluate and validate HIV viral load measurement from DBS in sub-Saharan Africa, with a reliable, all-automated, standard commercial assay such as the Abbott m2000. METHODS A...

متن کامل

Quantification of HIV-RNA from dried blood spots using the Siemens VERSANT® HIV-1 RNA (kPCR) assay.

OBJECTIVES Simplified methods for virological monitoring in resource-limited settings are increasingly needed. We evaluated the performance of the VERSANT(®) HIV-1 RNA (kPCR) assay for the determination of HIV-1 viral load from dried blood spots (DBS). Assay sensitivity and correlation with plasma quantification values were assessed. METHODS A total of 98 DBS were prepared from fresh blood sa...

متن کامل

Use of multiple competitors for quantification of human immunodeficiency virus type 1 RNA in plasma.

Quantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma has rapidly become an important tool in basic HIV research and in the clinical care of infected individuals. Here, a quantitative HIV assay based on competitive reverse transcription-PCR with multiple competitors was developed. Four RNA competitors containing identical PCR primer binding sequences as the viral HIV-1 RNA...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 136  شماره 

صفحات  -

تاریخ انتشار 2012