Glucose concentration in capillary blood of dairy cows obtained by a minimally invasive lancet technique and determined with three different hand-held devices.
نویسندگان
چکیده
BACKGROUND Dairy cows have a massive demand for glucose at the onset of lactation. A poor adaption to this period leads to an excessive negative energy balance with an increased risk for ketosis and impaired animal health and production. Besides the measurement of ketones, analysing the glucose concentration in blood is reported as helpful instrument for diagnosis and differentiation of ketosis. Monitoring metabolic parameters requires multiple blood sampling. In other species, new blood sampling techniques have been introduced in which small amounts of blood are rapidly analysed using electronic hand-held devices. The objective of this study was to evaluate the suitability of capillary blood for blood glucose measurement in dairy cows using the hand-held devices FreeStyle Precision (FSP, Abbott), GlucoMen LX Plus (GLX, A. Menarini) and the WellionVet GLUCO CALEA, (WGC, MED TRUST). In total, 240 capillary blood samples were obtained from dry and fresh lactating Holstein-Friesian cows. Blood was collected from the skin of the exterior vulva by using a lancet. For method comparison, additional blood samples were taken from a coccygeal vessel and analyzed in a laboratory. Glucose concentrations measured by a standard laboratory method were defined as the criterion standard. RESULTS The Pearson correlation coefficients between the glucose concentrations analyzed in capillary blood with the devices and the reference were 73% for the FSP, 81% for the GLX and 41% for the WGC. Bland-Altman plots showed biases of -18.8 mg/dL for the FSP, -11.2 mg/dL for the GLX and +20.82 mg/dL for the WGC. The optimized threshold determined by a Receiver Operating Characteristics analysis to detect hyperglycemia using the FSP was 43 mg/dL with a sensitivity (Se) and specificity (Sp) of 76 and 80%. Using the GLX and WGC optimized thresholds were 49 mg/dL (Se = 92%, Sp = 85%) and 95 mg/dL (Se = 39%, Sp = 92%). CONCLUSIONS The results of this study demonstrate good performance characteristics for the GLX and moderate for the FSP to detect hyperglycemia in dairy cows using capillary blood. With the study settings, the WGC was not suitable for determination of glucose concentrations.
منابع مشابه
مقایسه میزان همخوانی یافتههای سنجش قندخون با استفاده از گلوکومتر ON CALL و گلوکوکارد با روش آزمایشگاهی استاندارد
Background: Diabetes Mellitus (DM) is one the most common chronic disease, with many complications including renal failure, blindness and non traumatic amputation. Prevention of complications is possible through monitoring and control of blood glucose levels. Considering how easy home blood glucose monitoring is, we decided to evaluate the performance of two available glucometers for detection...
متن کاملNon-invasive Optical Techniques for determination of blood Glucose levels: A Review Article
This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...
متن کاملThresholds of whole-blood β-hydroxybutyrate and glucose concentrations measured with an electronic hand-held device to identify ovine hyperketonemia.
Metabolic disorders, especially hyperketonemia, are very common in dairy sheep. The whole-blood concentrations of β-hydroxybutyrate (BHBA) and glucose can be determined by commercially available electronic hand-held devices, which are used in human medicine and for the detection of ketosis in dairy cows. The aim of this study was to evaluate the suitability of the hand-held device Precision Xce...
متن کاملMilk Production, Milk Fatty Acid Profiles and Blood Metabolites in Holstein Dairy Cows Fed Diets Based on Dried Citrus Pulp
The objective of the present study was to determine the effect of substitution of corn grain with dried citrus pulp (DCP) on milk composition, fatty acids profiles and blood metabolites in Holstein dairy cows. These parameters were measured in a replicated 4 × 4 latin square design experiment using eight Holstein cows. Each experimental period lasted 4 weeks. The four treatments were: control (...
متن کاملBlood gases and metabolite content and ruminal fermentation in response to diets with different fermentability in Holstein dairy cows
The objective of this study was to determine the effects of diets having different fermentability on blood gases, blood metabolites and ruminal fermentation parameters in Holstein dairy cows. Four multiparous Holstein dairy cows (665 ± 25 kg BW, 170 ± 7.0 DIM and 15±1.5 kg of milk yield), fitted with rumen cannulae, were used in a 4×4 Latin Square design with 28-d periods. Corn starch and sucro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- BMC veterinary research
دوره 12 شماره
صفحات -
تاریخ انتشار 2016