Correlation of IOP with Corneal Acoustic Impedance in Porcine Eye Model
نویسندگان
چکیده
PURPOSE The aim of this study is to correlate the intraocular pressure (IOP) change with the acoustic impedance of the cornea, in order to propose a noncontact and noninvasive method for IOP monitoring. METHODS AND MATERIALS A highly focused transducer (frequency 47-MHz; bandwidth 62%) was made to measure the echo from the anterior and posterior surfaces of intact porcine eyes, respectively. A multilayered transmission and reflection model was used to calculate the acoustic impedance. The linear relationship between acoustic impedance and intraocular pressure was analyzed by statistical method. RESULT During pressure elevation from 10 mm Hg to 50 mm Hg, the mean acoustic impedance of the posterior cornea increased from 1.5393 to 1.5698 MRayl, which showed a strong linear correlation (R = 0.9849; P = 0.0022). Meanwhile, the mean value of the anterior cornea increased from 1.5399 to 1.5519 MRayl, and a less significant correlation was observed (R = 0.7378; P = 0.0025). CONCLUSION This study revealed a linear correlation between intraocular pressure and acoustic impedance of the cornea, thus demonstrating a potentially important method to noninvasively measure the intraocular pressure in vivo.
منابع مشابه
Corneal Ectasis among Wrestlers: Report of Two Cases
Report keratoconus in two patients with a long history of wrestling without any risk factor for corneal ectasia and reviewing the possible pathogenesis. To confirm suspicion of keratoconus, corneal topography was performed using scanning slit topography system and Orbscan. In two wrestlers with the complaint of visual loss in their eyes and IOP raising, corneal topography was performed and de...
متن کاملبررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن
To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...
متن کاملPorcine model to compare real-time intraocular pressure during LASIK with a mechanical microkeratome and femtosecond laser.
PURPOSE To compare real-time intraocular pressure (IOP) during laser in situ keratomileusis (LASIK) in porcine eyes using two types of microkeratomes. METHODS An interventional, prospective study of two microkeratomes: a Moria 2 (Moria group) and an IntraLase femtosecond laser (IntraLase Corp., Irvine, CA; IntraLase group). These devices were used to create lamellar corneal flaps in freshly e...
متن کاملNumerical model of optical coherence tomographic vibrography imaging to estimate corneal biomechanical properties
Most techniques measuring corneal biomechanics in vivo are biased by side factors. We demonstrate the ability of optical coherence tomographic (OCT) vibrography to determine corneal material parameters, while reducing current prevalent restrictions of other techniques (such as intraocular pressure (IOP) and thickness dependency). Modal analysis was performed in a finite-element (FE) model to st...
متن کاملCorrelation of Serial Scleral and Corneal Pneumatonometry.
PURPOSE To evaluate the usefulness of scleral pneumatonometry as an alternative for corneal measurements of intraocular pressure (IOP) over a broad range of IOPs. DESIGN Prospective, observational cohort study. PARTICIPANTS The study was conducted in the University of California, San Francisco, Retina Clinic between August and November 2013 in 33 adult patients (age range, 34-94 years; mean...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2017 شماره
صفحات -
تاریخ انتشار 2017