2D imaging of ultrasound fields using CCD array to map output of Fabry-Perot polymer film sensor
نویسندگان
چکیده
A 2D ultrasound field imaging system that uses a CCD array to map the optical output of a planar Fabry-Perot polymer film sensing interferometer is described. This system enables ultrasound fields to be rapidly mapped over a 6.6 4.7 mm aperture with spatial and temporal resolutions of the order of 10 mm and 10 ns, respectively. The concept was successfully demonstrated by imaging the acoustic field at the focus of a pulsed 5 MHz PZT ultrasound transducer. The technique offers an alternative to piezoelectric-based methods for high-resolution biomedical and industrial ultrasonic imaging and field characterisation applications.
منابع مشابه
Single-pixel optical camera for video rate ultrasonic imaging
A coherent-light single-pixel camera was used to interrogate a Fabry–Perot polymer film ultrasound sensor, thereby serially encoding a time-varying 2D ultrasonic field onto a single optical channel. By facilitating compressive sensing, this device enabled video rate imaging of ultrasound fields. In experimental demonstrations, this compressed sensing capability was exploited to reduce motion bl...
متن کاملFabry Perot polymer film fibre-optic hydrophones and arrays for ultrasound field characterisation
An optical ultrasound sensing method based upon the detection of acousticallyinduced changes in the optical thickness of a Fabry Perot (FP) polymer film sensing interferometer has been developed as an alternative to piezoelectric based detection methods for ultrasound measurement applications. The technique provides an inherently broadband (~30MHz) response and excellent detection sensitivities...
متن کاملA Fabry-Perot fibre-optic hydrophone for the measurement of ultrasound induced temperature changes
A wideband fibre optic hydrophone system based on a polymer film Fabry-Perot interferometer has been developed for the measurement of ultrasound fields. The sensor transduction mechanism is based upon the interferometric detection of acoustically-induced changes in the optical thickness of the polymer film. The system is also sensitive to temperature change due to thermal expansion of the polym...
متن کاملUltra high sensitivity, wideband Fabry Perot ultrasound sensors as an alternative to piezoelectric PVDF transducers for biomedical photoacoustic detection
A high sensitivity, wideband ultrasound sensor based on a high finesse Fabry-Perot (FP) polymer film interferometer has been demonstrated with a bandwidth of 20 MHz and a 50μm diameter active area. Used in conjunction with a balanced photodetector to enable the use of a high intensity interrogating light beam of up to 36mW, the sensor system provided a noise equivalent pressure (NEP) of 0.35kPa...
متن کامل2D backward-mode photoacoustic imaging system for NIR (650-1200nm) spectroscopic biomedical applications
A 2D photoacoustic imaging system for spectroscopic biomedical applications is reported, based on a Fabry-Perot (FP) polymer film ultrasound sensor. A variety of broadband sensors have been developed with bandwidths from 20MHz to 50MHz. These ultrasound sensors have a unique dichroic design which has an optical transmission window from 650nm to 1200nm and can be interrogated in the 1520-1610nm ...
متن کامل