Predictability of orthodontic movement with orthodontic aligners: a retrospective study
نویسندگان
چکیده
BACKGROUND The aim of this study was to evaluate the predictability of F22 aligners (Sweden & Martina, Due Carrare, Italy) in guiding teeth into the positions planned using digital orthodontic setup. METHODS Sixteen adult patients (6 males and 10 females, mean age 28 years 7 months) were selected, and a total of 345 teeth were analysed. Pre-treatment, ideal post-treatment-as planned on digital setup-and real post-treatment models were analysed using VAM software (Vectra, Canfield Scientific, Fairfield, NJ, USA). Prescribed and real rotation, mesiodistal tip and vestibulolingual tip were calculated for each tooth and, subsequently, analysed by tooth type (right and left upper and lower incisors, canines, premolars and molars) to identify the mean error and accuracy of each type of movement achieved with the aligner with respect to those planned using the setup. RESULTS The mean predictability of movements achieved using F22 aligners was 73.6%. Mesiodistal tipping showed the most predictability, at 82.5% with respect to the ideal; this was followed by vestibulolingual tipping (72.9%) and finally rotation (66.8%). In particular, mesiodistal tip on the upper molars and lower premolars were achieved with the most predictability (93.4 and 96.7%, respectively), while rotation on the lower canines was the least efficaciously achieved (54.2%). CONCLUSIONS Without the use of auxiliaries, orthodontic aligners are unable to achieve programmed movement with 100% predictability. In particular, although tipping movements were efficaciously achieved, especially at the molars and premolars, rotation of the lower canines was an extremely unpredictable movement.
منابع مشابه
Changes in force associated with the amount of aligner activation and lingual bodily movement of the maxillary central incisor
OBJECTIVE The purposes of this study were to measure the orthodontic forces generated by thermoplastic aligners and investigate the possible influences of different activations for lingual bodily movements on orthodontic forces, and their attenuation. METHODS Thermoplastic material of 1.0-mm in thickness was used to manufacture aligners for 0.2, 0.3, 0.4, 0.5, and 0.6 mm activations for lingu...
متن کاملApical root resorption during orthodontic treatment with aligners? A retrospective radiometric study
INTRODUCTION Objective of this study was to investigate the incidence and severity of apical root resorptions (ARR) during orthodontic treatment with aligners. MATERIALS AND METHODS The sample comprised 100 patients (17-75 years of age) with a class I occlusion and anterior crowding before treatment, treated exclusively with aligners (Invisalign®, Align Technologies, Santa Clara, CA, USA). Th...
متن کاملInvisalign with Photobiomodulation: Optimizing Tooth Movement and Treatment Efficacy with a Novel Self-Assessment Algorithm.
laser and light-emitting diode (LED) photobiomodulation (PBM).6 PBM is of particular interest because it is noninvasive and its mechanisms of action are well known, targeting the mitochondria by means of photochemical effects to promote bone remodeling.7,8 Additionally, it has been shown to accelerate a variety of orthodontic therapies, including both fixed appliances9,10 and Invisalign. Publis...
متن کاملتأثیر متقابل درمانهای اندودنتیک و ارتودنتیک
The purpose of this article was reviewing the literature related to the mutual effects of endodontics and orthodontics on each other providing documented information that can be used by dentists in clinical practice. The effect of orthodontic treatment on the dental pulp and its role in root resorption, the influence of previous trauma to the tooth and endodontic treatment in orthodontic tooth ...
متن کاملA Comparative Study Regarding the Deformation Values of Orthodontic Aligners
Orthodontic therapy using aligners is a modern treatment option among adult patients. In order to have an optimal control of the orthodontic resuslts, there is a need for knowing the deformation values that can appear in each type of aligner, the optimal thickness values of the appliances and the needed number of aligners for each case. The deformation values for a 0.2 mm repositioned lower cen...
متن کامل