DTI at 7 and 3 T: systematic comparison of SNR and its influence on quantitative metrics.
نویسندگان
چکیده
Diffusion tensor imaging (DTI) and advanced related methods such as diffusion spectrum and kurtosis imaging are limited by low signal-to-noise ratio (SNR) at conventional field strengths. DTI at 7 T can provide increased SNR; however, B0 and B1 inhomogeneity and shorter T2⁎ still pose formidable challenges. The purpose of this study was to quantify and compare SNR at 7 and 3 T for different parallel imaging reduction factors, R, and TE, and to evaluate SNRs influences on fractional anisotropy (FA) and apparent diffusion coefficient (ADC). We found that R>4 at 7 T and R≥2 at 3 T were needed to reduce geometric distortions due to B0 inhomogeneity. For these R at 7 T, SNR was 70-90 for b=0 s/mm(2) and 22-28 for b=1000s/mm(2) in central brain regions. SNR was lower at 3 T (40 for b=0 s/mm(2) and 15 for b=1000 s/mm(2)) and in lateral brain regions at 7 T due to B1 inhomogeneity. FA and ADC did not change with MRI field strength, SENSE factor or TE in the tested range. However, the coefficient of variation for FA increased for SNR <15 and for SNR <10 in ADC, consistent with published theoretical studies. Our study demonstrates that 7 T is advantageous for DTI and lays the groundwork for further development. Foremost, future work should further address challenges with B0 and B1 inhomogeneity to take full advantage for the increased SNR at 7 T.
منابع مشابه
Metrics and Evaluation Tools for Patient Engagement in Healthcare Organization- and System-Level Decision-Making: A Systematic Review
Background Patient, public, consumer, and community (P2C2) engagement in organization-, community-, and systemlevel healthcare decision-making is increasing globally, but its formal evaluation remains challenging. To define a taxonomy of possible P2C2 engagement metrics and compare existing evaluation tools against this taxonomy, we conducted a systematic review. Methods A broad search strate...
متن کاملUsing the Taxonomy and the Metrics: What to Study When and Why; Comment on “Metrics and Evaluation Tools for Patient Engagement in Healthcare Organization- and System-Level Decision-Making: A Systematic Review”
Dukhanin and colleagues’ taxonomy of metrics for patient engagement at the organizational and system levels has great potential for supporting more careful and useful evaluations of this ever-growing phenomenon. This commentary highlights the central importance to the taxonomy of metrics assessing the extent of meaningful participation in decision-making by patients, consumers and community mem...
متن کاملClinically feasible NODDI characterization of glioma using multiband EPI at 7 T
Recent technological progress in the multiband echo planer imaging (MB EPI) technique enables accelerated MR diffusion weighted imaging (DWI) and allows whole brain, multi-b-value diffusion imaging to be acquired within a clinically feasible time. However, its applications at 7 T have been limited due to B1 field inhomogeneity and increased susceptibility artifact. It is an ongoing debate wheth...
متن کاملA voxel-based analysis of SNR effect on diffusion tensor imaging
Introduction: Fractional anisotropy (FA) quantifies microstructural organization of various anatomical structures, especially the distinct differences between white and gray matter. The study of FA value differences between normal and clinical groups has been the primary focus of various brain research areas. However, the value of FA is very sensitive to low signal-to-noise ratio (SNR) in diffu...
متن کاملDetermination of the optimum filter for qualitative and quantitative 99mTc myocardial SPECT imaging
Background: Butterworth, Gaussian, Hamming, Hanning, and Parzen are commonly used SPECT filters during filtered back-projection (FBP) reconstruction, which greatly affect the quality and size accuracy of image. Materials and Methods: This study involved a cardiac phantom in which 1.10 cm thick cold defect was inserted into its myocardium wall and filled with 4.0 μCi/ml (0.148 MBq/ml) 99mTc conc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance imaging
دوره 29 6 شماره
صفحات -
تاریخ انتشار 2011