Measurement of Optimal Insertion Angle for Iliosacral Screw Fixation Using Three-Dimensional Computed Tomography Scans

نویسندگان

  • Jung-Jae Kim
  • Chul-Young Jung
  • Jonathan G. Eastman
  • Hyoung-Keun Oh
چکیده

BACKGROUND Percutaneous iliosacral screw fixation can provide stable fixation with a minimally invasive surgical technique for unstable posterior pelvic ring injuries. This surgical technique is not limited by cases of difficult fracture patterns, sacral dysplasia, and small sacral pedicles that can occur in Asians. The purpose of this study was to investigate the incidence of the sacral dysplasia in the Korean population and determine the optimal direction of iliosacral screws by analyzing pelvic three-dimensional computed tomography (3D-CT) scans. METHODS One hundred adult patients who had pelvic 3D-CT scans were evaluated. The upper sacral morphology was classified into three groups, i.e., normal, transitional, and dysplastic groups; the cross-sectional area of the safe zone was measured in each group. S1 pedicle with a short width of more than 11 mm was defined as safe pedicle. The incidences of safe pedicles at different angles ranging from 0° to 15° were investigated in order to determine optimal angle for screw direction. RESULTS The incidence of normal, transitional, and dysplastic group was 46%, 32%, and 22%, respectively. There were significant increases of the cross-sectional area of the safe zones by increasing the angles from 0° to 15° in all groups. The incidence of safe pedicles increased similar to the changes in cross-sectional area. The overall incidence of safe pedicles was highest at the 10° tilt angle. CONCLUSIONS The incidence of sacral dysplasia in Koreans was 54%, which is higher than previous studies for Western populations. The cross-sectional area of the safe zone can be increased by anteromedial direction of the iliosacral screw. Considering the diversity of sacral morphology present in the Korean population, a tilt angle of 10° may be the safest angle.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Finite Element Model of Electrode Placement During Stimulus Evoked Electromyographic Monitoring of Iliosacral Screw Insertion

Pelvic ring fractures that occur as a result of substantial orthopedic trauma are frequently repaired using iliosacral screws to stabilize the fracture. Stimulus evoked electromyography, using pulsed current stimuli provided through the drill bit cathode, has been advocated to prevent nerve root injury during iliosacral screw insertion. Our objective was to examine the effects of anode location...

متن کامل

The safe screw path along inferior border of the arcuate line at acetabular area: an anatomical study based on CT scans

BACKGROUND Misplaced screw during the internal fixation of acetabular fractures may penetrate the hip joint which might cause chondrolysis and traumatic osteoarthritis in the future. This study aims to acquire the safe path for screw insertion along inferior border of the arcuate line fixation route at acetabular area. METHODS Computed tomography (CT) scans of 98 patients without pelvic traum...

متن کامل

Anatomic Determinants of Sacral Dysmorphism and Implications for Safe Iliosacral Screw Placement.

BACKGROUND Upper sacral segment dysplasia increases the risk of cortical perforation during iliosacral screw insertion. Dysmorphic sacra have narrow and angled upper osseous corridors. However, there is no validated definition of this anatomic variation. We hypothesized that pelves could be quantitatively grouped by anatomic measurements. METHODS One hundred and four computed tomography (CT) ...

متن کامل

A Finite Element Study of Electrode Location during Stimulus Evoked Electromyographic Monitoring of Iliosacral Screw Insertion

INTRODUCTION: Pelvic ring fractures are a relatively common form of orthopaedic trauma. While mechanical stability may be restored by the insertion of iliosacral screws, the proximity of the ideal screw trajectory to the fifth lumbar and first sacral nerve roots (S1), as well as the spinal canal make nervous tissue injury a potential hazard. Fluoroscopy has typically been used to ensure proper ...

متن کامل

Three-dimensional spiral CT measurement of atlantal pedicle and its clinical application

The study aimed to establish the safe placement area and corresponding entry angle of atlantal pedicle screw using axial computed tomography (CT) measurement of atlas, in order to guide the clinical operation. Spiral thin-slice CT scan of atlas and three-dimensional reconstruction of 38 patients were randomly selected. Screw placement space was defined as the distance between the tangent lines ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2016