Investigation of the halo-artifact in 68Ga-PSMA-11-PET/MRI
نویسندگان
چکیده
OBJECTIVES Combined positron emission tomography (PET) and magnetic resonance imaging (MRI) targeting the prostate-specific membrane antigen (PSMA) with a 68Ga-labelled PSMA-analog (68Ga-PSMA-11) is discussed as a promising diagnostic method for patients with suspicion or history of prostate cancer. One potential drawback of this method are severe photopenic (halo-) artifacts surrounding the bladder and the kidneys in the scatter-corrected PET images, which have been reported to occur frequently in clinical practice. The goal of this work was to investigate the occurrence and impact of these artifacts and, secondly, to evaluate variants of the standard scatter correction method with regard to halo-artifact suppression. METHODS Experiments using a dedicated pelvis phantom were conducted to investigate whether the halo-artifact is modality-, tracer-, and/or concentration-dependent. Furthermore, 31 patients with history of prostate cancer were selected from an ongoing 68Ga-PSMA-11-PET/MRI study. For each patient, PET raw data were reconstructed employing six different variants of PET scatter correction: absolute scatter scaling, relative scatter scaling, and relative scatter scaling combined with prompt gamma correction, each of which was combined with a maximum scatter fraction (MaxSF) of MaxSF = 75% or MaxSF = 40%. Evaluation of the reconstructed images with regard to halo-artifact suppression was performed both quantitatively using statistical analysis and qualitatively by two independent readers. RESULTS The phantom experiments did not reveal any modality-dependency (PET/MRI vs. PET/CT) or tracer-dependency (68Ga vs. 18F-FDG). Patient- and phantom-based data indicated that halo-artifacts derive from high organ-to-background activity ratios (OBR) between bladder/kidneys and surrounding soft tissue, with a positive correlation between OBR and halo size. Comparing different variants of scatter correction, reducing the maximum scatter fraction from the default value MaxSF = 75% to MaxSF = 40% was found to efficiently suppress halo-artifacts in both phantom and patient data. In 1 of 31 patients, reducing the maximum scatter fraction provided new PET-based information changing the patient's diagnosis. CONCLUSION Halo-artifacts are particularly observed for 68Ga-PSMA-11-PET/MRI due to 1) the biodistribution of the PSMA-11-tracer resulting in large OBRs for bladder and kidneys and 2) inaccurate scatter correction methods currently used in clinical routine, which tend to overestimate the scatter contribution. If not compensated for, 68Ga-PSMA-11 uptake pathologies may be masked by halo-artifacts leading to false-negative diagnoses. Reducing the maximum scatter fraction was found to efficiently suppress halo-artifacts.
منابع مشابه
Integrated 68Ga-HBED-CC-PSMA-PET/MRI in patients with suspected recurrent prostate cancer.
AIM Evaluate the diagnostic accuracy of 68Ga-labeled HBED-CC-PSMA-PET/MRI for detection of recurrent PCa in comparison to PET/CT. METHODS 48 patients with suspected recurrent PCa underwent PET/CT after injection of the 68Ga-HBED-CC-PSMA ligand followed by integrated PET/MRI. Image analysis was performed by nuclear medicine physicians and radiologists with respect to the detection of lymph nod...
متن کامل68Ga-PSMA-11 PET/CT for prostate cancer staging and risk stratification in Chinese patients
We evaluated the clinical utility of 68Ga-PSMA-11 PET/CT for staging and risk stratification of treatment-naïve prostate cancer (PCa) and metastatic castrate-resistant prostate cancer (mCRPC). Twenty-two consecutive patients with treatment-naïve PCa and 18 with mCRPC were enrolled. 68Ga-PSMA-11 PET/CT and magnetic resonance imaging (MRI) were performed for the evaluation of primary prostatic le...
متن کاملOptimal MRI sequences for 68Ga-PSMA-11 PET/MRI in evaluation of biochemically recurrent prostate cancer
BACKGROUND PET/MRI can be used for the detection of disease in biochemical recurrence (BCR) patients imaged with 68Ga-PSMA-11 PET. This study was designed to determine the optimal MRI sequences to localize positive findings on 68Ga-PSMA-11 PET of patients with BCR after definitive therapy. Fifty-five consecutive prostate cancer patients with BCR imaged with 68Ga-PSMA-11 3.0T PET/MRI were retros...
متن کاملManual production and quality control of 68Ga-PSMA-11 radiopharmaceutical for PET-CT imaging of prostate cancer: optimization and 60 production series experience
Background: 68Ga-PSMA-11, a novel PET radiopharmaceutical, is currently used for imaging of almost all prostate cancers. However, automatic radiolabeling procedures have been recommended. In this research, according to the chemical nature of the PSMA-11, manual, optimized and safe production of this radiopharmaceutical has been investigated and a standard method has been presented to achieve a ...
متن کامل[68Ga]Ga-PSMA-11 PET/CT for staging and patient management of high-risk prostate cancer: A single-center experience from Iran
Introduction: Accurate staging plays an important role in management of patients with prostate cancer especially in high-risk group. Today, [68Ga]Ga-PSMA-11 PET/CT should be considered as the preferred imaging tool for treatment planning and initial staging of the disease. Methods: A total number of 628 patients with prostate cancer referred to...
متن کامل