High-throughput quantification of lysophosphatidylcholine by electrospray ionization tandem mass spectrometry.

نویسندگان

  • Gerhard Liebisch
  • Wolfgang Drobnik
  • Bernd Lieser
  • Gerd Schmitz
چکیده

BACKGROUND Lysophosphatidylcholine (LPC) has been suggested to play a functional role in various diseases, including atherosclerosis, diabetes, and cancer mediated by LPC-specific G-protein-coupled receptors. Initial studies provided evidence for a potential use of LPC as diagnostic maker. However, existing methodologies are of limited value for a systematic evaluation of LPC species concentrations because of complicated, time-consuming procedures. We describe a methodology based on electrospray ionization tandem mass spectrometry (ESI-MS/MS) applicable for high-throughput LPC quantification. METHODS Crude lipid extracts of EDTA-plasma samples were used for direct flow injection analysis. LPC 13:0 and LPC 19:0 were added as internal standards, and the ESI-MS/MS was operated in the parent-scan mode for m/z 184. Quantification was achieved by standard addition. Data processing was highly automated by use of the mass spectrometer software and self-programmed Excel macros. RESULTS The calibrators LPC 16:0, LPC 18:0, and LPC 22:0 showed a linear response independent of sample dilution and plasma cholesterol concentration for both internal standards. The within-run imprecision (CV) was 3% for the major and 12% for the minor species, whereas the total imprecision was approximately 12% for the major and 25% for the minor species. The detection limit was <1 micromol/L. CONCLUSION The developed ESI-MS/MS methodology with an analysis time of 2 min/sample, simple sample preparation, and automated data analysis allows high-throughput quantification of distinct LPC species from plasma samples, which could be a valuable tool for the evaluation of LPC as diagnostic marker.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Liquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization

A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...

متن کامل

Method validation of clonidine hydrochloride in human plasma by LC-MS technique

A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile&ndash;water 60:40 (v/v), and 0.2% formic acid 20 &micro;L of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm&times;30 m...

متن کامل

Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma

A rapid and sensitive liquid chromatography&ndash;tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 48 12  شماره 

صفحات  -

تاریخ انتشار 2002