Validation of noninvasive indices of global systolic function in patients with normal and abnormal loading conditions: a simultaneous echocardiography pressure-volume catheterization study.

نویسندگان

  • Raquel Yotti
  • Javier Bermejo
  • Yolanda Benito
  • Ricardo Sanz-Ruiz
  • Cristina Ripoll
  • Pablo Martínez-Legazpi
  • Candelas Pérez del Villar
  • Jaime Elízaga
  • Ana González-Mansilla
  • Alicia Barrio
  • Rafael Bañares
  • Francisco Fernández-Avilés
چکیده

BACKGROUND Noninvasive indices based on Doppler echocardiography are increasingly used in clinical cardiovascular research to evaluate left ventricular global systolic chamber function. Our objectives were to clinically validate ultrasound-based methods of global systolic chamber function to account for differences between patients in conditions of abnormal load, and to assess their sensitivity to load confounders. METHODS AND RESULTS Twenty-seven patients (8 dilated cardiomyopathy, 10 normal ejection fraction, and 9 end-stage liver disease) underwent simultaneous echocardiography and left heart catheterization with pressure-conductance instrumentation. The reference index, maximal elastance (Emax), was calculated from pressure-volume loop data obtained during acute inferior vena cava occlusion. A wide range of values were observed for left ventricular systolic chamber function (Emax: 2.8±1.0 mm Hg/mL), preload, and afterload. Among the noninvasive indices tested, the peak ejection intraventricular pressure difference showed the best correlation with Emax (R=0.75). A significant but weaker correlation with Emax was observed for ejection fraction (R=0.41), midwall fractional shortening (R=0.51), global circumferential strain (R=-0.53), and strain rate (R=-0.46). Longitudinal strain and strain rate failed to correlate with Emax, as did noninvasive single-beat estimations of this index. Principal component and multiple regression analyses demonstrated that peak ejection intraventricular pressure difference was less sensitive to load, whereas ejection fraction and longitudinal strain and strain rate were heavily influenced by afterload. CONCLUSIONS Current ultrasound methods have limited accuracy to characterize global left ventricular systolic chamber function in a given patient. The Doppler-derived peak ejection intraventricular pressure difference should be preferred for this purpose because it best correlates with the reference index and is more robust in conditions of abnormal load.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی عوارض قلبی در بیماران مبتلا به تالاسمی ماژور در کاشان در سالهای 1378 لغایت 1379

ABSTRACT Due to the frequency of major thalassemia in our country and cardiac complications secondry to iron overload as one of the most important causes of death in these patients and the absence of any similar study in this region (Kashan city), we studied the cardiac complications in patients with major thalassemia in Kashan in 1999 and 2000. A prospective descriptive study was perf...

متن کامل

LEFT VENTRICULAR DIASTOLIC ABNORMALITIES IN β-THALASSEMIA MAJOR WITH NORMAL SYSTOLIC FUNCTION

In order to identify left ventricular diastolic function in patients with betathalassemia major and normal systolic function by noninvasive M-mode and Doppler echocardiography, an analytic study was designed in a university hospital in Sari. We have studied 44 patients (23 men and 21 women), mean age 15.48±2.16 (range 12 to 20) and 43 age and sex matched control subjects. Peak flow velocit...

متن کامل

Left ventricular untwisting rate by speckle tracking echocardiography.

BACKGROUND Recent studies validated the measurement of left ventricular (LV) untwisting rate (UR) by speckle tracking echocardiography. A few reports suggest that it may provide additional noninvasive insight into LV diastolic function. METHODS AND RESULTS Simultaneous echocardiographic imaging and LV pressure measurements (7F Millar catheters) were performed in 8 adult dogs. Loading conditio...

متن کامل

بررسی ارزش سونوگرافی داپلر در تشخیص رد پیوند کلیه

Background and purpose: Doppler sonography is a noninvasive diagnostic procedure with no side effect witch is cost effective and the results are rapidly available. Two indices are explained in the field of Doppler sonographic hemodynamic evaluation, PÏ* and RÏ**, Âbnormal ranges are PÏ ≥ 1.8 and RÏ ≥ 0.7 . Ïn previous studies average PÏ in normal conditions was 1.5 and in rejected trans...

متن کامل

Assessment of left ventricular pressure-volume relations using gated radionuclide angiography, echocardiography, and micromanometer pressure recordings. A new method for serial measurements of systolic and diastolic function in man.

This study was designed to validate the use of combined invasive and noninvasive methods in assessing serial pressure-volume relations in man. Ten patients undergoing cardiac catheterization were studied with simultaneous intracardiac micromanometer pressure recordings, gated radionuclide angiography and echocardiography. Systolic and diastolic function were measured at rest, during right atria...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation. Cardiovascular imaging

دوره 7 1  شماره 

صفحات  -

تاریخ انتشار 2014