Inmetro’s Primary and Secundary Measurement Standard Systems for Zener References Calibration
نویسندگان
چکیده
In this paper, the primary (Josephson-based) and secundary (Zener-based) measurement standard systems used for calibration of solid state voltage standards (Zeners) at Inmetro are described, as well as the calibration method, the related equations and uncertainty budgets.
منابع مشابه
Rapport BIPM-2011/05: The BIPM 1.018 V Zener Measurement Set-up
A new measurement set-up for calibration of secondary DC voltage standards at the level of 1.018 V has been developed by the Bureau International des Poids et Mesures (BIPM). A metrological validation process was developed to ensure the correct operation of the new set-up and to demonstrate its consistency with the previous set-up. Firstly, a direct comparison of two primary voltage standards s...
متن کاملElectrical Quantities in Terms of the International System of Units
--The electrical International System of Units (SI) are defined and realized as DC electrical quantities. National Institute for Standards (NIS), Egypt maintains the DC voltage unit by using the DC Josephson Voltage Standard (JVS) as a primary standard for DC voltage adding to eight zener diode reference standards as DC voltage secondary standards. The JVS is used to provide traceability of ele...
متن کاملMagnetic Calibration of Three-Axis Strapdown Magnetometers for Applications in Mems Attitude-Heading Reference Systems
In a strapdown magnetic compass, heading angle is estimated using the Earth's magnetic field measured by Three-Axis Magnetometers (TAM). However, due to several inevitable errors in the magnetic system, such as sensitivity errors, non-orthogonal and misalignment errors, hard iron and soft iron errors, measurement noises and local magnetic fields, there are large error between the magnetometers'...
متن کاملSelecting a Primary Frequency Standard for a Calibration Laboratory
Calibration laboratories can choose from a variety of frequency standards, including quartz oscillators, atomic oscillators, and oscillators disciplined to agree with reference signals from the Global Positioning System (GPS) satellites or other sources. The frequency calibration and measurement capability of a laboratory is largely determined by the type of primary frequency standard* that is ...
متن کاملStandard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...