Transient response harmonic imaging: an ultrasound technique related to brain perfusion.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Gray-scale harmonic imaging is the first method to visualize blood perfusion and capillary blood flow with ultrasound after intravenous contrast agent application. The purpose of the present study was to evaluate the potential of transient response second harmonic imaging (TRsHI) to assess normal echo contrast characteristics in different brain areas by transcranial ultrasound. METHODS In 18 patients without cerebrovascular diseases, TRsHI examinations were performed bilaterally with the use of the transtemporal approach after application of 6.5 mL of a galactose-based microbubble suspension (400 mg/mL). The transmission rate was once every 4 cardiac cycles. Regional cerebral contrast was visually assessed and then quantified off-line with the use of time-intensity curves. In 4 different regions of interest (ROI) (posterior part of the thalamus [ROIa], anterior part of the thalamus [ROIb], lentiform nucleus [ROIc], and white matter [ROId]), the following parameters were evaluated: peak intensity, area under the curve (AUC), and time to peak intensity. AUC ratios for ROIc/a, d/a, c/b, and d/b were calculated. RESULTS In all patients parenchymal contrast enhancement was visually detectable. One hundred thirty-one characteristic time-intensity curves (baseline phase, peak contrast intensity, slow washout phase) were demonstrable in 144 ROIs. In ROIc and ROId, characteristic contrast curves could be observed most frequently (68/72 examinations), whereas time-intensity curves in ROIa and ROIb could not be evaluated because of inadequate contrast enhancement in 9 of 72 examinations. Time to peak intensity varied between 20 and 52 cardiac cycles; in 1 patient it was 88 cardiac cycles. In all individuals AUCs and in 16 of 18 subjects peak intensity in ROIc and ROId showed a 2- to 10-fold increase compared with ROIa and ROIb. In no examination did AUC ratios show a >2-fold side difference irrespective of the ROI. CONCLUSIONS The present study demonstrates for the first time that TRsHI produces accurate contrast in different brain areas and represents an ultrasonic tool related to brain perfusion. Absolute values of quantitative parameters show high variations caused by different temporal bone thicknesses and a complex relationship between echo contrast concentrations and measurements of optic intensities. Ratios between different ROIs help to compare contrast enhancement in different brain areas. Furthermore, because of the fact that attenuation of contrast enhancement in TRsHI depends strictly on the insonation depth, harmonic imaging studies of brain perfusion cannot be compared directly with other imaging techniques such as positron emission tomography.
منابع مشابه
Comparison of transcranial brain tissue perfusion images between ultraharmonic, second harmonic, and power harmonic imaging.
BACKGROUND AND PURPOSE To clarify optimal brain tissue perfusion images visualized by transcranial ultrasound harmonic imaging, we compared gray-scale integrated backscatter (IBS) images of new ultraharmonic imaging (UHI) and conventional second harmonic imaging (SHI) with power harmonic imaging (PHI) (harmonic B-mode with harmonic power Doppler images) in 10 patients with and 4 without a tempo...
متن کاملSecond harmonic imaging: a new ultrasound technique to assess human brain tumour perfusion.
BACKGROUND Second harmonic imaging is a new ultrasound technique that allows evaluation of brain tissue perfusion after application of an ultrasound contrast agent. OBJECTIVE To evaluate the potential of this technique for the assessment of abnormal echo contrast characteristics of different brain tumours. METHODS 27 patients with brain tumours were studied. These were divided into four gro...
متن کاملUltrasound perfusion imaging of the human brain.
BACKGROUND AND PURPOSE Color-coded perfusion maps can be calculated from ultrasound harmonic gray-scale imaging data to analyze brain tissue perfusion. METHODS In 13 healthy volunteers, 2 doses (0.5 and 1.5 mL) of Optison, a perfluoropropane-containing ultrasound contrast agent, were injected intravenously, and they produced a strong increase in echo enhancement in the brain parenchyma. The c...
متن کاملDifferent aspects of transient ischemic dilation
Transient ischemic left ventricular dilation (TID) is a marker of severe and extensive coronary artery disease as well as an increased risk of adverse outcomes. The patients with more severe and extensive ischemia, multivessel-type of perfusion abnormality as well as patients with left anterior descending artery (LAD) territory perfusion abnormality have more probab...
متن کاملPerfusion imaging of free flaps with contrast harmonic ultrasound imaging, laser-induced indocyanine green fluorescence angiography and magnetic resonance imaging
Currently there is no image-guided modality which is sufficient and exact enough to evaluate the perfusion of tissue in its different layers after transplantation of microvascular flaps. Examination of capillary filling after compression (refill) allows merely a vague estimation. The cutaneous blood flow can be shown with different methods of fluoroscopy, but the perfusion of deeper tissue laye...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 29 9 شماره
صفحات -
تاریخ انتشار 1998