چکیده

ulatory standard for minimizing potentihealth effects arising from their ingestion in drinking water (5). Other common inorganic anions, such as fluoride, chloride, and sulfate, are considered secondary contaminants and are regulated under the U.S. National Secondary Drinking Water Standards, which are guidelines for taste, color, odor, and certain aesthetic effects (6). Although bromide is not regulated under these standards, it is a precursor to bromate, which is regulated under the NPDWS, and therefore, most water-supply systems are required to analyze for bromide. Many of the other countries previously mentioned have health standards similar to the United States for the anions specified. Since the mid-1980s, IC has been approved for compliance monitoring of these inorganic anions in drinking water, as described in EPA Method 300.0 Part A (7). In 1992, this same method was recommended for promulgation by the EPA-Environmental Monitoring Systems Laboratory (EMSL, Cincinnati, Ohio) for compliance monitoring in all EPA regions for the determination of inorganic anions in wastewater under the National Pollution Discharge Elimination System Program (4). EPA Method 300.0 Part A describes the use of an IonPac AS4A anion-exchange column The United States Environmental Protection Agency (EPA) Office of Water has determined that the use of hydroxide eluents in EPA Methods 300.0 and 300.1 is acceptable for compliance monitoring of common inorganic anions by ion chromatography under the Clean Water Act (CWA) and the Safe Drinking Water Act (SDWA). The authors evaluated the performance of a high-capacity anion-exchange column specifically designed for use with hydroxide eluents for fulfilling the requirements of EPA Method 300.0 Part A and compared the results with data generated with an anion-exchange column using carbonate eluents. The high-capacity anion-exchange column used with an on-line electrolytically generated potassium hydroxide eluent yielded improved calibration linearity (r2 . 0.999), improved retention-time stability (, 0.05% RSD for most anions), and comparable or better method detection limits. Determination of Common Inorganic Anions in Environmental Waters Using a Hydroxide Selective Column

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of inorganic anions in environmental waters with a hydroxide-selective column.

US Environmental Protection Agency Method 300.0 specifies the use of an IonPac AS4A anion-exchange column with a carbonate-hydrogencarbonate eluent and suppressed conductivity detection for the determination of inorganic anions in environmental waters by ion chromatography. Hydroxide eluents have not typically been used for the routine analysis of common inorganic anions due to the lack of an a...

متن کامل

Determination of anions at trace levels in power plant water samples by ion chromatography with electrolytic eluent generation and suppression.

An ion chromatographic method was developed for the determination of nine inorganic and organic acid anions at sub- to low-microg/l levels in power plant water samples. In this method, samples were injected using a large-volume direct injection technique, the analyte anions were separated on a hydroxide-selective anion-exchange column using high-purity hydroxide eluents generated by an on-line ...

متن کامل

Determination of trace levels of haloacetic acids and perchlorate in drinking water by ion chromatography with direct injection.

Disinfection by products of haloacetic acids and perchlorate pose significant health risks, even at low microg/l levels in drinking water. A new method for the simultaneous determination of nine haloacetic acids (HAAs) and perchlorate as well as some common anions in one run with ion chromatography was developed. The HAAs tested included mono-, di-, trichloroacetic acids, mono, di-, tribromoace...

متن کامل

Determination of Anions in Acid Rain by Ion Chromatography

INTRODUCTION The increase in acidity of wet and dry atmospheric depositions has been attributed to the increase of SO 2 and NO 2 emissions from stationary and mobile pollution sources. The acid rain problem has reached dramatic proportions throughout many regions of the United States, Europe, Canada, and Japan. Monitoring air and rain is essential, not only for assessing the effects of pollutan...

متن کامل

Ion chromatographic separations of phosphorus species: a review.

The aim of this paper is to review recent literature regarding the determination of phosphorus species by ion chromatography (IC), and describe the implementation of new developments in sample treatment and ion chromatography methodology for the analysis of these compounds. Ion-exchange methods using both carbonate/hydrogencarbonate and hydroxide selective columns in combination with self-regen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004