The effect of freeze-thawing on magnetic resonance imaging T2* of freshly harvested bovine patellar tendon.
نویسندگان
چکیده
BACKGROUND Analysis of fresh specimens in research studies is ideal; however, it is often necessary to freeze samples for evaluation at a later time. Limited evaluation of the effect of freeze-thawing of tendon tissue samples on inherent magnetic resonance imaging (MRI) parameters, such as ultrashort echo time (UTE) T2* values, have been performed to date. METHODS This study performed UTE MRI on 14 bovine patellar tendons at harvest and after four consecutive freeze-thaw cycles. RESULTS Results demonstrated a small but significant reduction (12%) in tendon T2* values after the first freeze thaw cycle, but not after successive cycles. Tendons from juvenile animals with open physis had a significant reduction of T2* following a single freeze thaw cycle, P<0.0001. CONCLUSIONS The results of this study emphasize the importance of using uniform tendon storage protocols when using UTE MRI in preclinical models.
منابع مشابه
Magnetic resonance imaging of feline eye
The purpose of this study was to investigate magnetic resonance imaging (MRI) of the normal feline eyeand optic nerves using T1-weighted and T2-weighted images. A total of 6 healthy female domestic short haircats age 2-2.5 years and weighing 3.2 ± 0.4 kg were selected. Magnetic resonance imaging data werecollected using GEMSOW (Philips) at a magnetic field strength of 1.5 T. Dorsal, sagittal, a...
متن کاملA New Potential Contrast Agent for Magnetic Resonance Imaging: Iron Oxide-4A Nanocomposite
Background: Magnetic resonance imaging (MRI) contrast agents have an important role to differentiate healthy and diseased tissues. Access and design new contrast agents for the optimal use of MRI are necessary. This study aims to evaluate iron oxide–4A nanocomposite ability to act as a magnetic resonance imaging contrast agent.Materials and Methods: Iron oxide–4A nanocomposite (F4A) was syn...
متن کاملChanges of the Patellar Tendon Moment arm Length in Different Knee Angles: A Biomechanical in Vivo Study
Patellar tendon moment arm length (PTma) changes at different knee flexion angles have not been determined in invivo studies. We aimed to determine PTma in four different knee angles using Magnetic Resonance Imaging (MRI) topredict in vivo changes in the moment arm length from different knee angles during running.PTma was measured as the perpendicular distance from muscle–tend...
متن کاملPatellar tendon re-rupture on the opposite end of the previous site of surgical repair
We describe a rare case of a patellar tendon "re-rupture" at the opposite end of a previous proximal tendon repair. A 32-year-old male with a history of surgically repaired right proximal patellar tendon rupture presented with an acute non-traumatic right knee pain and instability during sports. Magnetic resonance imaging confirmed a complete rupture of his distal patellar tendon at the tibial ...
متن کاملEvaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major
Background: Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Quantitative imaging in medicine and surgery
دوره 5 3 شماره
صفحات -
تاریخ انتشار 2015