Evaluation of a new autofocus algorithm within the framework of Fast Factorized Back-Projection

نویسندگان

  • Jan Torgrimsson
  • P. Dammert
  • L. Eriksson
  • H. Hellsten
  • L. Ulander
  • A. Åhlander
چکیده

The following report deals with a new autofocus algorithm within the framework of time domain SAR processing (Fast Factorized BackProjection). The strategy, developed at SAAB EDS, relies on varying flight track parameters until a sharp image is obtained. Focus measures are provided by a predetermined object function. After a short introduction and some preliminaries, the algorithm is described in detail, results for two different data sets (collected by the CARABAS II system) are then presented, analyzed and discussed. The analysis emphasizes some promising attributes. Two of the autofocused images are for example sharper than corresponding references. It is also shown that two of the variation parameters are separable, this reduces the required number of geometry hypotheses substantially. However, some issues are also raised. A point-like target is for example easily distorted unless the data is upsampled prior to the processing. For the moment, it is not clear if this problem is related to the back-projection or the autofocus algorithm itself. The time consumption is another distinct downside. The report concludes that a lot of work remains to be done before the algorithm can be considered as functional. A sensitivity study with respect to the variation parameters, as well as a search for alternative object functions should be prioritized. A more conventional autofocus approach is also proposed, to keep options open for the future.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Fast back-projection algorithm for Bistatic SAR with parallel trajectory

Exploiting the fundamental redundancy between nearby aperture positions for high frequency reflectivity components in the along-track direction, we will propose a factorized back-projection algorithm for bistatic SAR with parallel trajectory inversion based on recursive partitioning of the back-projection integral. The basic back-projection summation is factorised into n processing stages, each...

متن کامل

A Robust Adaptive Observer-Based Time Varying Fault Estimation

This paper presents a new observer design methodology for a time varying actuator fault estimation. A new linear matrix inequality (LMI) design algorithm is developed to tackle the limitations (e.g. equality constraint and robustness problems) of the well known so called fast adaptive fault estimation observer (FAFE). The FAFE is capable of estimating a wide range of time-varying actuator fault...

متن کامل

A New RSTB Invariant Image Template Matching Based on Log-Spectrum and Modified ICA

Template matching is a widely used technique in many of image processing and machine vision applications. In this paper we propose a new as well as a fast and reliable template matching algorithm which is invariant to Rotation, Scale, Translation and Brightness (RSTB) changes. For this purpose, we adopt the idea of ring projection transform (RPT) of image. In the proposed algorithm, two novel s...

متن کامل

An Empirical Transmitted EPID Dosimetry Method using a Back-Projection Algorithm

Background: The present study aimed to introduce a rapid transmission dosimetry through an electronic portal-imaging device (EPID) to achieve two-dimensional (2D) dose distribution for homogenous environments. Material and Methods: In this Phantom study, first, the EPID calibration curve and correction coefficients for field size were obtained from EPID and ionization chamber. Second, the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011