Multislice perfusion imaging in human brain using the C-FOCI inversion pulse: comparison with hyperbolic secant.
نویسندگان
چکیده
Perfusion studies based on pulsed arterial spin labeling have primarily applied hyperbolic secant (HS) pulses for spin inversion. To optimize perfusion sensitivity, it is highly desirable to implement the HS pulse with the same slice width as the width of the imaging pulse. Unfortunately, this approach causes interactions between the slice profiles and manifests as residual signal from static tissue in the resultant perfusion image. This problem is currently overcome by increasing the selective HS width relative to the imaging slice width. However, this solution increases the time for the labeled blood to reach the imaging slice (transit time), causing loss of perfusion sensitivity as a result of T(1) relaxation effects. In this study, we demonstrate that the preceding problems can be largely overcome by use of the C-shaped frequency offset corrected inversion (FOCI) pulse [Ordidge et al., Magn Reson Med 1996;36:562]. The implementation of this pulse for multislice perfusion imaging on the cerebrum is presented, showing substantial improvement in slice definition in vivo compared with the HS pulse. The sharper FOCI profile is shown to reduce the physical gap (or "safety margin") between the inversion and imaging slabs, resulting in a significant increase in perfusion signal without residual contamination from static tissue. The mean +/- SE (n = 6) gray matter perfusion-weighted signal (DeltaM/M(o)) without the application of vascular signal suppression gradients were 1.19 +/- 0. 10% (HS-flow-sensitive alternating inversion recovery [FAIR]), and 1. 51 +/- 0.11% for the FOCI-FAIR sequence. The corresponding values with vascular signal suppression were 0.64 +/- 0.14%, and 0.91 +/- 0. 08% using the HS- and FOCI-FAIR sequences, respectively. Compared with the HS-based data, the FOCI-FAIR results correspond to an average increase in perfusion signal of up to between 26%-30%. Magn Reson Med 42:1098-1105, 1999.
منابع مشابه
Reducing Contamination in PASL using BASSI RF pulses
Introduction Arterial spin labeling is sensitive to contamination due to off-resonance effects of the RF label. While it has been argued that in PASL these effects are small compared to pulse profile effects [1], this assessment has to be re-evaluated in view of the advent of highly selective gradient-modulated adiabatic pulses such as FOCI [2], requiring several times more RF energy than the c...
متن کاملHyperbolic secant parameter optimization for non-selective inversion at 7 T
Fig. 2 Results for three HS pulses: a high bandwidth pulse (row 1), a reduced bandwidth pulse (row 2), and an optimized pulse with reduced bandwidth (row 3). Flip-angle maps are calculated on the grid of targeted static and RF field variations (column 1) and within an axial slice of the human brain (column 2). Frequency profiles for B1/ B1,nom intensities of 0.35, 0.50, 0.75, and 1.00 are shown...
متن کاملAdiabatic inversion pulses for myocardial T1 mapping.
PURPOSE To evaluate the error in T1 estimates using inversion-recovery-based T1 mapping due to imperfect inversion and to perform a systematic study of adiabatic inversion pulse designs in order to maximize inversion efficiency for values of transverse relaxation (T2) in the myocardium subject to a peak power constraint. METHODS The inversion factor for hyperbolic secant and tangent/hyperboli...
متن کاملContinuous arterial spin labeling using a train of adiabatic inversion pulses.
PURPOSE To develop a simple and robust magnetic resonance imaging (MRI) pulse sequence for the quantitative measurement of blood flow in the brain and cerebral tumors that has practical implementation advantages over currently used continuous arterial spin labeling (CASL) schemes. MATERIALS AND METHODS Presented here is a single-coil protocol that uses a train of hyperbolic secant inversion p...
متن کاملA protocol for assessing subtraction errors of arterial spin-tagging perfusion techniques in human brain.
A protocol for assessing signal contributions from static tissue (subtraction errors) in perfusion images acquired with arterial spin-labeling (ASL) techniques in human brain is proposed. The method exploits the reduction of blood T(1) caused by the clinically available paramagnetic contrast agent, gadopentetate dimeglumine (Gd-DTPA). The protocol is demonstrated clinically with multislice FAIR...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 42 6 شماره
صفحات -
تاریخ انتشار 1999