Fabricating customized hydrogel contact lens
نویسندگان
چکیده
Contact lenses are increasingly used in laboratories for in vivo animal retinal imaging and pre-clinical studies. The lens shapes often need modification to optimally fit corneas of individual test subjects. However, the choices from commercially available contact lenses are rather limited. Here, we report a flexible method to fabricate customized hydrogel contact lenses. We showed that the fabricated hydrogel is highly transparent, with refractive indices ranging from 1.42 to 1.45 in the spectra range from 400 nm to 800 nm. The Young's modulus (1.47 MPa) and hydrophobicity (with a sessile drop contact angle of 40.5°) have also been characterized experimentally. Retinal imaging using optical coherence tomography in rats wearing our customized contact lenses has the quality comparable to the control case without the contact lens. Our method could significantly reduce the cost and the lead time for fabricating soft contact lenses with customized shapes, and benefit the laboratorial-used contact lenses in pre-clinical studies.
منابع مشابه
Dynamic contour tonometry over silicone hydrogel contact lens.
PURPOSE This study compared the measurements of intraocular pressure (IOP) and ocular pulse amplitude (OPA) using the Dynamic Contour Tonometry (DCT) over silicone hydrogel contact lenses of different modulus. Corneal biomechanics were also measured using the Ocular Response Analyzer (ORA). METHODS Forty-seven young (mean age 22.3 years, standard deviation 1.2 years) subjects had IOP, OPA, co...
متن کاملAdhesion of Pseudomonas aeruginosa and Staphylococcus epidermidis to silicone-hydrogel contact lenses.
PURPOSE The purpose of this study is to compare the adhesion capabilities of the most important etiologic agents of microbial ocular infection to the recently available silicone-hydrogel lenses with those to a conventional hydrogel lens. METHODS In vitro static adhesion assays of Pseudomonas aeruginosa 10,145, Staphylococcus epidermidis 9142 (biofilm-positive), and 12,228 (biofilm-negative) t...
متن کاملIncidence of keratitis of varying severity among contact lens wearers.
AIM To determine the incidence of non-severe keratitis (NSK) and severe keratitis (SK) among wearers of current generation contact lenses. METHODS A 12 month, prospective, hospital based epidemiological study was conducted by examining all contact lens wearers presenting with a corneal infiltrate/ulcer to a hospital centre in Manchester. A clinical severity matrix was used to differentiate be...
متن کاملContinuing education CET
● Tear film assessment should be undertaken with minimal invasion of the structure – non-invasive techniques should be used whenever possible ● Assessment must be made both prior to and during contact lens wear. Tear film quality should be assessed both with the lens in situ and without the lens ● Use of the Tearscope in clinical practice allows a more detailed examination of the tears to be un...
متن کاملThe influence of surface treatment on hydrophobicity, protein adsorption and microbial colonisation of silicone hydrogel contact lenses.
PURPOSE To evaluate the influence of surface treatment of silicone-hydrogel CL on lens hydrophobicity, protein adsorption and microbial colonisation by studying several silicone hydrogel contact lenses (CL) with and without surface treatment. The lenses used in this study were Balafilcon A, Lotrafilcon A, Lotrafilcon B and Galyfilcon A. A conventional hydrogel CL (Etafilcon A) was also tested. ...
متن کامل