An investigation of the performance of Biostop G and Hardinge bone plugs.

نویسندگان

  • P J Prendergast
  • P Birthistle
  • D V Waide
  • N V Kumar
چکیده

Although distal plugging is a common procedure to prevent distal flow of polymethyl-methacrylate (PMMA) cement during cementing of femoral prostheses, there is little biomechanical testing to confirm that (a) the plugs do not displace under cementing pressure, and (b) they do in fact occlude cement flow. Two designs of femoral intramedullary plugs, the Biostop G (Bioland, France) and Hardinge (De Puy, Leeds, UK) were examined to determine their performance under cement pressurization in a biomechanical test. A testing rig was fabricated in which distal migration could be measured as a function of cement pressurization. Sectioning of the samples after polymerization of the cement revealed the extent of cement flow. The results show that, even in this well controlled test, there is significant variability in plug performance. It is shown that the Biostop G displaces less than the Hardinge for similar cement pressures. Sectioning reveals that cement can escape around the Hardinge plug at high pressures. Furthermore, a pore forming effect of the Biostop G plug was occasionally observed indicating that design improvements may be possible for this plug.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in Vitro Comparative Study of the Performance of Different Commercially Available Intramedullary Femoral Plugs during Total Hip Replacement

Distal flow of polymethylmethacrylate (PMMA) bone cement during insertion of the femoral implant results in reduced pressure and cement-bone interdigitation (Markolf, Amstutz, 1976). Insertion of femoral cement plugs in the intramedullary canal to prevent distal flow of PMMA cement in total hip replacement during cementing of femoral prostheses is well accepted and has become current practice (...

متن کامل

A comparison of distal canal restrictors in primary cemented femoral hip arthroplasty.

A retrospective study evaluated 75 total hip arthroplasties performed over a 4-year period using 4 different cement restrictors. A harvested bone restrictor, polyethylene restrictor (Smith & Nephew, Richards Inc, Memphis, Tenn), Biostop G (Depuy Orthopaedics, Warsaw, Ind), and polymethylmethacrylate (PMMA) (Wright Medical Technology, Arlington, Tex) were compared for the percentage of failures,...

متن کامل

An investigation on the effects of juvenile rainbow trout (Oncorhynchus mykiss) and brook trout (Salvelinus fontinalis) monoculture and duo-culture farming in freshwater and seawater on growth performance

The objective of this study was to compare growth performance and feed conversion ratios of rainbow trout (Oncorhynchus mykiss) and brook trout (Salvelinus fontinalis) juveniles in monoculture and duo-culture in freshwater and seawater under aquarium conditions. The fish were about 2-months old hatchery-reared brook and rainbow trout with initial weights of 0.934±0.033 (n=360) and 1.014±0.019 (...

متن کامل

Effect of dietary available phosphorus and phytase on production performance of old laying hens and tibia bone quality

Background: Old laying hens are more prone to dietary calcium (Ca) and phosphorus (P) deficiencies as  they absorb Ca and P less efficiently than younger hens. OBJECTIVES: In a 2×2 factorial design, the influence of diets with two levels of available phosphorus (AP) and phytase enzyme on the laying performance, egg quality and tibia bone characteristics of laying hens at their late 2nd producti...

متن کامل

Effect of Impact Parameters on Explosive Welding of Tube to a Plug

Effects of some important parameters like impactor effects, plug geometry and initiation points on bonding aluminum tubes to aluminum plugs were studied. The impact velocity and dynamic angle between tube and plug should be precisely managed to achieve an optimum bonding condition. A new explosive bonding technique with the use of two material impactors was proposed. Results are especially suit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 213 4  شماره 

صفحات  -

تاریخ انتشار 1999