Region-specific mechanical properties of the human patella tendon.

نویسندگان

  • B T Haraldsson
  • P Aagaard
  • M Krogsgaard
  • T Alkjaer
  • M Kjaer
  • S P Magnusson
چکیده

The present study investigated the mechanical properties of tendon fascicles from the anterior and posterior human patellar tendon. Collagen fascicles from the anterior and posterior human patellar tendon in healthy young men (mean +/- SD, 29.0 +/- 4.6 yr, n = 6) were tested in a mechanical rig. A stereoscopic microscope equipped with a digital camera recorded elongation. The fascicles were preconditioned five cycles before the failure test based on pilot data on rat tendon fascicle. Human fascicle length increased with repeated cycles (P < 0.05); cycle 5 differed from cycle 1 (P < 0.05), but not cycles 2-4. Peak stress and yield stress were greater for anterior (76.0 +/- 9.5 and 56.6 +/- 10.4 MPa, respectively) than posterior fascicles (38.5 +/- 3.9 and 31.6 +/- 2.9 MPa, respectively), P < 0.05, while yield strain was similar (anterior 6.8 +/- 1.0%, posterior 8.7 +/- 1.4%). Tangent modulus was greater for the anterior (1,231 +/- 188 MPa) than the posterior (583 +/- 122 MPa) fascicles, P < 0.05. In conclusion, tendon fascicles from the anterior portion of the human patellar tendon in young men displayed considerably greater peak and yield stress and tangent modulus compared with the posterior portion of the tendon, indicating region-specific material properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanical properties of human patellar tendon at the hierarchical levels of tendon and fibril.

Tendons are strong hierarchical structures, but how tensile forces are transmitted between different levels remains incompletely understood. Collagen fibrils are thought to be primary determinants of whole tendon properties, and therefore we hypothesized that the whole human patellar tendon and its distinct collagen fibrils would display similar mechanical properties. Human patellar tendons (n ...

متن کامل

In vivo human tendon mechanical properties: effect of resistance training in old age.

Recent advances in ultrasound scanning have made it possible to obtain the mechanical properties of human tendons in vivo. Application of the in vivo method in elderly individuals showed that their patellar tendons stiffened in response to a 14-week resistance training program by approximately 65% both structurally and materially. The rate of muscle torque development increased by approximately...

متن کامل

Evaluating changes in tendon crimp with fatigue loading as an ex vivo structural assessment of tendon damage.

The complex structure of tendons relates to their mechanical properties. Previous research has associated the waviness of collagen fibers (crimp) during quasi-static tensile loading to tensile mechanical properties, but less is known about the role of fatigue loading on crimp properties. In this study (IACUC approved), mouse patellar tendons were fatigue loaded while an integrated plane polaris...

متن کامل

Influence of decorin and biglycan on mechanical properties of multiple tendons in knockout mice.

Evaluations of tendon mechanical behavior based on biochemical and structural arrangement have implications for designing tendon specific treatment modalities or replacement strategies. In addition to the well studied type I collagen, other important constituents of tendon are the small proteoglycans (PGs). PGs have been shown to vary in concentration within differently loaded areas of tendon, ...

متن کامل

Lower strength of the human posterior patellar tendon seems unrelated to mature collagen cross-linking and fibril morphology.

The human patellar tendon is frequently affected by tendinopathy, but the etiology of the condition is not established, although differential loading of the anterior and posterior tendon may be associated with the condition. We hypothesized that changes in fibril morphology and collagen cross-linking would parallel differences in material strength between the anterior and posterior tendon. Tend...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 98 3  شماره 

صفحات  -

تاریخ انتشار 2005