Influence of sampling site and flow area on cardiac output measurements by Doppler echocardiography.

نویسندگان

  • H Dittmann
  • W Voelker
  • K R Karsch
  • L Seipel
چکیده

In 40 patients cardiac output was simultaneously determined by pulsed Doppler echocardiography and thermodilution (range 4.0 to 10.2 liters/min). The sample volume was located in the center of the mitral anulus, at the tips of the mitral leaflets and in the center of the aortic anulus. Circular cross-sectional areas of the mitral anulus, aortic anulus and aortic bulbus were calculated from M-mode and two-dimensional echocardiographic diameters. The varying short axis of the elliptical mitral opening area was obtained from the diastolic leaflet separation in the M-mode, and the long axis was derived from the maximal mitral orifice area or mitral anulus diameter. Cardiac output was calculated by multiplying time-velocity integrals with the different areas and heart rate. Doppler flow measurements correlated significantly with the thermodilution method (r = 0.79 to 0.93). Flow measurements at the aortic anulus were most accurate (r = 0.93, SEE = 0.589 liter/min) if the annular area was derived from the M-mode tracing. Measurement of the anulus in the apical five chamber view yielded a significant underestimation and the area of the aortic bulbus provided an overestimation of cardiac output. Left ventricular inflow was underestimated at the mitral leaflet tips and overestimated at the mitral anulus. The accuracy of pulsed Doppler cardiac output measurements strongly depends on the assumed flow area and sampling site. Both should be determined at the same level in the inflow or outflow tract of the left ventricle. Measurement of cardiac output in the center of the aortic anulus provided the highest accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of variations of pulsed Doppler sampling site on calculation of cardiac output: an experimental study in open-chest dogs.

We measured aortic flow by two-dimensional Doppler echocardiography in an open-chest dog model to examine how variations in Doppler sample volume length and position influence aortic hemodynamic flow calculations. Fourteen dogs underwent right-heart bypass, in which venous return from the venae cavae drained by gravity to a reservoir. A variable-speed roller pump returned the blood to the pulmo...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

The Mitral Valve Orifice Method for Noninvasive Two - dimensional Echo Doppler Determinations of Cardiac Output DANIEL

We developed and validated a mitral valve orifice method for Doppler cardiac output determination. In 15 open-chest dogs, cardiac output was controlled and measured by a roller pump interposed between the right atrium and pulmonary artery as a right-heart bypass. Left heart flows were measured in the open-chest dog model by Doppler measurements at the mitral valve orifice and compared not only ...

متن کامل

Normal Echocardiographic Findings in Healthy Pigeons

Objective- The purpose of this study was to investigate the feasibility of performing echocardiography in apparently healthy pigeons, and measurement of the quantitative cardiac indices using B-mode and Doppler techniques. Design- Experimental study Animals- Ten apparently healthy pigeons Procedures- Echocardi...

متن کامل

The mitral valve orifice method for noninvasive two-dimensional echo Doppler determinations of cardiac output.

We developed and validated a mitral valve orifice method for Doppler cardiac output determination. In 15 open-chest dogs, cardiac output was controlled and measured by a roller pump interposed between the right atrium and pulmonary artery as a right-heart bypass. Left heart flows were measured in the open-chest dog model by Doppler measurements at the mitral valve orifice and compared not only ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 10 4  شماره 

صفحات  -

تاریخ انتشار 1987