Fiducial registration error and target registration error are uncorrelated [7261-1]

نویسنده

  • J. Michael Fitzpatrick
چکیده

Image-guidance systems based on fiducial registration typically display some measure of registration accuracy based on the goodness of fit of the fiducials. A common measure is fiducial registration error (FRE), which equals the root-meansquare error in fiducial alignment between image space and physical space. It is natural for the surgeon to regard the displayed estimate of error as an indication of the accuracy of the system’s ability to provide guidance to surgical targets for a given case. Thus, when the estimate is smaller than usual, it may be assumed that the target registration error (TRE) is likely to be smaller than usual. We show that this assumption, while intuitively convincing, is in fact wrong. We show it in two ways. First, we prove to first order that for a given system with a given level of normally distributed fiducial localization error, all measures of goodness of fit are statistically independent of TRE, and therefore FRE and TRE are uncorrelated. Second, we demonstrate by means of computer simulations that they are uncorrelated for the exact problem as well. Since TRE is the true measure of registration accuracy of importance to the success of the surgery, our results show that no estimate of accuracy for a given patient that is based on goodness of fiducial fit for that patient gives any information whatever about true registration accuracy for that patient. Therefore surgeons should stop using such measures as indicators of registration quality for the patients on whom they are about to operate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Geometrical analysis of registration errors in point-based rigid-body registration using invariants

Point-based rigid registration is the method of choice for aligning medical datasets in diagnostic and image-guided surgery systems. The most clinically relevant localization error measure is the Target Registration Error (TRE), which is the distance between the image-defined target and the corresponding target defined on another image or on the physical anatomy after registration. The TRE dire...

متن کامل

Analytic Expressions for Fiducial and Surface Target Registration Error

We propose and test analytic equations for approximating expected fiducial and surface target registration error (TRE). The equations are derived from a spatial stiffness model of registration. The fiducial TRE equation is equivalent to one presented by. We believe that the surface TRE equation is novel, and we provide evidence from computer simulations to support the accuracy of the approximat...

متن کامل

The role of registration in accurate surgical guidance.

Registration is presented as the central issue of surgical guidance. The focus is on the accuracy of approaches employed today, all of which use pre-operative images to guide surgery on rigid anatomy. The three most well-established approaches to guidance, namely the stereotactic frame, point fiducials, and surface matching, are examined in detail, together with two new approaches based on micr...

متن کامل

"Worst-case analysis of target localization errors in fiducial based rigid body registration"

Fiducial-based rigid registration is the preferred method for aligning the preoperative image with the intra-operative physical anatomy in existing image-guided surgery systems. After registration, the targets locations usually cannot be measured directly, so the Target Registration Error (TRE) is often estimated with the Fiducial Registration Error (FRE), or with Fitzpatrick TRE (FTRE) estimat...

متن کامل

Optimal landmarks selection and fiducial marker placement for minimal target registration error in image-guided neurosurgery

We describe a new framework and method for the optimal selection of anatomical landmarks and optimal placement of fiducial markers in image-guided neurosurgery. The method allows the surgeon to optimally plan the markers locations on routine diagnostic images before preoperative imaging and to intraoperatively select the fiducial markers and the anatomical landmarks that minimize the Target Reg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009