A new and universal free/bound separation technique for the "CENTRIA" automated radioimmunoassay system.

نویسندگان

  • B Mériadec
  • J P Jolu
  • R Henry
چکیده

A new separation procedure based on the double-antibody technique has been adapted to the CENTRIA System. This procedure is universally applicable and lends itself to easy adaptation to commercial RIA kits in which liquid reagents are used. This second antibody is covalently linked to agarose (Sepharose) and the lyophilized powder is subsequently tableted for easy use on the instrument. The technique was applied to radioimmunoassay for thyrotropin (thyroid stimulating hormone), alpha-fetoprotein, and ferritin. Performance characteristics were as follows: sensitivity 1.5 milliunits/L, 4.5 micrograms/L, and 4.5 micrograms/L, respectively; intrarun precision 1.7, 9, and 3.4%, and interrun precision 7.6, 13, and 14.5%. All three assays were clinically validated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated approach to radioimmunoassays of somatotropin (human growth hormone) and insulin.

The adaptation of human somatotropin and insulin assays to the automated Centria radioimmunoassay system [Clin. Chem. 21, 1305 (1975)] is reported. For the somatotropin assay, reaction conditions include a borate/bovine serum albumin buffer (pH 8.4) AND 20-H Incubation at 4 degrees C. Assay results for clinical samples compared favorably (correlation coefficient = 0.930) with values obtained fr...

متن کامل

Retrieval–travel-time model for free-fall-flow-rack automated storage and retrieval system

Automated storage and retrieval systems (AS/RSs) are material handling systems that are frequently used in manufacturing and distribution centers. The modelling of the retrieval–travel time of an AS/RS (expected product delivery time) is practically important, because it allows us to evaluate and improve the system throughput. The free-fall-flow-rack AS/RS has emerged as a new technology for dr...

متن کامل

Performance characteristics of three automated immunoassays for thyroid hormones

Background: Since the introduction of the first radioimmunoassay, several improvements have been made in the design of immunoassays such as method of antibody production, labeling, automation and detection technology. We performed an analytical evaluation of the new electrochemiluminescent immunoassay (ECLIA) for serum TSH, FT4 and T3 in the Elecsys 2010 immunoassay system and compared the resu...

متن کامل

A fully automated, continuous-flow radioimmunoassay for methotrexate.

We describe a fully automated continuous-flow radioimmunoassay for methotrexate. [125I]Histamine-labeled methotrexate was used as tracer. Anti-methotrexate serum was coupled to a magnetizable solid-phase and the bound and free fractions were separated with an electromagnetic field. The assay is precise (CV less than 2.5%) and rapid (30 samples per hour), incubation volume is small (about 160 mi...

متن کامل

Discrete modular system for automation of radioimmunoassay of serum choriomammotropin.

We describe a discrete automated radioimmunoassay system for determining choriomammotropin (placental lactogen) in human serum. With the present system it can be measured in as many as 37 unknown sera (50 muL) and three quality-control sera, in duplicate, within 1.5 h. The time required for sample preparation, incubation (15 min), and separation of free and bound radioactivities (a 150 mL/L pol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 9  شماره 

صفحات  -

تاریخ انتشار 1979