Closed-Form Analytical Investigation of Space-Vector PWM Inverter Fed Induction Motor Drive under DC-Bus Voltage Pulsation

نویسنده

  • JIRI KLIMA
چکیده

Abstract-Voltage sag or unbalance conditions at the input rectifier stage of the ac-dc-ac rectifier-inverter induction motor drive can cause the significant amounts of harmonic voltage at twice the line frequency 2f1. This voltage ripple can have a degrading effect on the induction-machine performance characteristics. This paper presents an analytical closed-form mathematical model and analysis of the impact of DC-bus ripple voltage of the three-phase voltage source inverter (VSI) with the space-vector PWM (SVPWM) on the induction machine phase voltages, currents and torque pulsations. The analytical expressions for the voltage and current space-vectors as a function of the DC-bus voltage pulsation are derived. From the current space vectors the torque behavior is estimated, again as a function of DC-link voltage pulsation. Next, it is shown, that DC-link voltage ripple components may cause large torque pulsation. The proposed analytical method is based on the mixed p-z approach [13], enabling presentation of the results in lucid and closed-form. To verify the effectiveness of the proposed analytical model, experimental results based on laboratory setup were performed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study and Analysis of Three Phase Voltage Source Inverter Fed Induction Motor Drive in Various Pulse Width Modulation Techniques

The Three Phase Voltage Source Inverter supplies invariably required variable voltage and frequency of the adjustable speed drive system. A number of pulse width modulation (PWM) schemes are used to obtain variable voltage and frequency supply from an inverter. The most widely used PWM scheme for a Three Phase Voltage Source Inverter is carrier based sinusoidal PWM and Space Vector Pulse Width ...

متن کامل

Comparison of MRAS Based Rotor Resistance Estimator Using Reactive Power and Flux Based Techniques for Space Vector PWM Inverter Fed Induction Motor Drives

The performance of Vector Controlled Induction Motor drive depends on the accuracy of rotor resistance which will vary with temperature and frequency. The MRAS approach using reactive power and flux as a state variable for rotor resistance estimation makes MRAS computationally simpler and easy to design. In this paper, Rotor Flux based MRAS (RF-MRAS) and Reactive Power based MRAS (RP-MRAS) for ...

متن کامل

Space Vector Pulse Width Modulation with Reduced Common Mode Voltage and Current Losses for Six-Phase Induction Motor Drive with Three-Level Inverter

Common-mode voltage (CMV) generated by the inverter causes motor bearing failures in multiphase drives.On the other hand, presence of undesired z-component currents in six-phase induction machine (SPIM) leads to extra current losses and have to be considered in pulse width modulation (PWM) techniques. In this paper, it is shown that the presence of z-component currents and CMV in six phase driv...

متن کامل

A Current-Source-Inverter-Fed Induction Motor Drive System with Reduced Losses

Standard lowand medium-power induction motor drives are based on the pulsewidth modulation (PWM) voltagesource inverter fed from a diode rectifier. The dual topology, based on the current-source inverter/rectifier structure is used in mediumand high-power applications. This paper analyzes the existing motor drives based on current-source topologies and proposes a control strategy that addresses...

متن کامل

Dual two-level inverter scheme for an open-end winding induction motor drive with a single DC power supply and improved DC bus utilisation - Electric Power Applications, IEE Proceedings-

A dual two-level inverter fed open-end winding induction motor drive with a single DCpower supply is proposed. The proposed scheme produces voltage space vector locations identical to those of a conventional three-level inverter. In the conventional neutral-clamped three-level inverter, the series-connected DC link capacitors carry the load current, resulting in a fluctuating neutral point. Als...