A comparison of mesopic visual acuity and objective visual quality following cataract surgery with hydrophobic acrylic intraocular lenses
نویسندگان
چکیده
PURPOSE To evaluate mesopic visual acuity and visual quality as measured by objective scatter index (OSI) in pseudophakic eyes with long-term follow-up after implantation of hydrophobic acrylic lenses made from two different lens materials. SETTING This study was carried out in a private clinic. DESIGN This study was an observational cohort study. METHODS This pilot study included 181 eyes of 136 patients who had undergone cataract surgery with implantation of monofocal hydrophobic acrylic intraocular lenses (IOLs), either Alcon AcrySof (82 eyes) or Abbott Medical Optics' Tecnis (99 eyes). The monocular corrected distance visual acuity (CDVA) of the subjects was recorded under mesopic room illumination and OSI was measured by an optical quality analysis system using double-pass wavefront method. RESULTS Mean follow-up duration was 60.07±18.82 months. Eyes implanted with Tecnis IOLs had statistically significantly better mesopic CDVA (0.08±0.08) compared to those implanted with AcrySof IOLs (0.11±0.07) (P=0.020). Mesopic CDVA of 20/25 or better was found in 79.8% of eyes in the Tecnis group compared to 62.2% of eyes in AcrySof group. Similarly, OSI was also found to be statistically significantly better for Tecnis IOLs compared to AcrySof IOL group (mean OSI, Tecnis: 1.65±0.92, AcrySof: 2.01±1.36; P=0.033). When glaucomatous eyes were excluded, OSI was still significantly better (P=0.028) in the Tecnis IOL group. CONCLUSION The eyes implanted with Tecnis IOLs showed better long-term optical performance in terms of both OSI and mesopic visual acuity in comparison to those with AcrySof IOLs.
منابع مشابه
کاربرد لنزهای داخل چشمی در جراحی کاتاراکت و عوامل تأثیرگذار بر دید بیمار
Introduction: With the growing and rapid development of refractive surgery, researches focus increasingly on improvement of visual quality after cataract surgery. Intraocular lenses (IOLs) were a successful effort in the field of cataract surgery. Despite significant advances in cataract surgery, several complications related to surgical technique and IOL design after surgery can cause vision c...
متن کاملComparison of hydrophobic and hydrophilic intraocular lens in preventing posterior capsule opacification after cataract surgery
BACKGROUND Posterior capsular opacification (PCO) is a common long-term complication of cataract surgery. Intraocular lens design and material have been implicated in influencing the development of PCO. This study evaluated the association of hydrophobic and hydrophilic intraocular lenses on preventing PCO. METHODS Medline, Cochrane, EMBASE, and Google Scholar databases were searched until Au...
متن کاملComparison of clinical results between heparin surface modified hydrophilic acrylic and hydrophobic acrylic intraocular lens.
PURPOSE To compare the clinical results of heparin surface modified (HSM) hydrophilic acrylic intraocular lens (IOL) with those of hydrophobic acrylic IOL. METHODS One hundred patients with cataract were randomized to receive one of acrylic foldable IOLs after phacoemulsification: HSM hydrophilic acrylic IOL (n=50) BioVue3 (BioVue, OII, Ontario, CA, USA) and hydrophobic acrylic IOL (n=50) Sen...
متن کاملReversible opacification of hydrophobic acrylic intraocular lens- two cases report
BACKGROUND The opacification of the intraocular lens (IOL) can cause significant visual deterioration. It is known that opacity of hydrophobic acrylic IOLs is rare. We report 2 cases of reversible optic opacification of hydrophobic acrylic intraocular lenses (Tecnis ZCB00, Abbott), observed within 2 months after uneventful cataract surgery. CASE PRESENTATION Case 1: Uneventful cataract surger...
متن کاملLaser capsulotomy following cataract surgery: Comparing time to capsulotomy with implantation of two broadly used intraocular lenses
PURPOSE The aim of this study is to compare the length of time from uneventful cataract surgery using one of two common posterior chamber intraocular lenses (IOLs) (hydrophilic versus hydrophobic acrylic) to laser capsulotomy. MATERIALS AND METHODS Retrospective analysis of all patients who underwent neodymium: yttrium-aluminum-garnet laser capsulotomy between 2011 and 2014 following uneventf...
متن کامل