Comparison of cardiac magnetic resonance imaging and bio-impedance spectroscopy for the assessment of fluid displacement induced by external leg compression.

نویسندگان

  • Salvatore Saporito
  • Silviu Dovancescu
  • Ingeborg H F Herold
  • Harrie C M van den Bosch
  • Hans C van Assen
  • Ronald M Aarts
  • Hendrikus H M Korsten
  • Massimo Mischi
چکیده

Heart failure is marked by frequent hospital admissions, often as a consequence of pulmonary congestion. Current gold standard techniques for thoracic fluid measurement require invasive heamodynamic access and therefore they are not suitable for continuous monitoring. Changes in thoracic impedance (TI) may enable non-invasive early detection of congestion and prevention of unplanned hospitalizations. However, the usefulness of TI to assess thoracic fluid status is limited by inter-subject variability and by the lack of reliable normalization methods. Indicator dilution methods allow absolute fluid volume estimation; cardiac magnetic resonance (CMR) has been recently proposed to apply indicator dilution methods in a minimally-invasive manner. In this study, we aim to compare bio-impedance spectroscopy (BIS) and CMR for the assessment of thoracic fluid status, and to determine their ability to detect fluid displacement induced by a leg compression procedure in healthy volunteers. A pressure gradient was applied across each subject's legs for 5 min (100-60 mmHg, distal to proximal). Each subject underwent a continuous TI-BIS measurement during the procedure, and repeated CMR-based indicator dilution measurements on a 1.5 T scanner at baseline, during compression, and after pressure release. The Cole-Cole and the local density random walk models were used for parameter extraction from TI-BIS and indicator dilution measurements, respectively. Intra-thoracic blood volume index (ITBI) derived from CMR, and extracellular fluid resistance (R E) from TI-BIS, were considered as thoracic fluid status measures. Eight healthy volunteers were included in this study. An increase in ITBI of 45.2  ±  47.2 ml m-2 was observed after the leg inflation (13.1  ±  15.1% w.r.t. baseline, p  <  0.05), while a decrease of  -0.84  ±  0.39 Ω in R E (-1.7  ±  0.9% w.r.t. baseline, p  <  0.05) was observed. ITBV and R E normalized by body mass index were strongly inversely correlated (r  =  -0.93, p  <  0.05). In conclusion, an acute fluid displacement to the thoracic circulation was induced in healthy volunteers. Significant changes were observed in the considered thoracic fluid measures derived from BIS and CMR. Good correlation was observed between the two measurement techniques. Further clinical studies will be necessary to prospectively evaluate the value of a combination of the two techniques for prediction of re-hospitalizations after admission for heart failure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of Organ Specific Iron Overload in Transfusion-dependent Thalassemia by Magnetic Resonance Imaging Techniques

The consequence of repeated blood transfusions in thalassemia is iron overload in different organs. Magnetic resonance imaging (MRI) is a reliable, non-invasive and accurate method for iron detection in various tissues, hence the introduction of MRI has revolutionized the management of these patients and improved the life expectancy of them. Cardiac MRI T2* has a profound effect not only on est...

متن کامل

DNA Damages on Blood Cells After Cardiac Magnetic Resonance Imaging

Introduction: Along with the increased use of cardiac imaging at clinics there is increased attention to the potential risks related to the methods used like magnetic resonance (MR) and it cannot be ruled out that MR can alter DNA structure. The aim of this review is to assess the impact of routine cardiac magnetic resonance (CMR) scanning on DNA damages in human T lymphocytes....

متن کامل

Cardiac and Hepatic T2*-Weighted Magnetic Resonance Imaging

Abstract Background Iron overload is the main transfusion related side effects in patients with transfusion dependent hemoglobinopathies. Severe iron deposition in tissues leads to organ dysfunction. Many organs can be affected such as heart, liver, and endocrine organs. Cardiac failure and liver fibrosis are the consequent of Iron overload in transfusion dependent hemoglobinopathy. Magne...

متن کامل

بررسی شدت نسبی سیگنال تصاویر Magnetic Resonance در بافت رترودیسکال و عضله پتریگوئید خارجی و رابطه آن با یافته‌های Magnetic Resonance Imaging

Background and Aims: Disc displacement is the most common temporomandibular joint disorder and magnetic resonance imaging (MRI) is the gold standard in its diagnosis. This disorder can lead to changes in signal intensity of magnetic resonance (MR). The purpose of this study was evaluation of correlation between relative signal intensity of MR images of retrodiscal tissue, superior and inferior ...

متن کامل

The modeling of induced current density in eyes from static magnetic fields produce by MR scanner

Introduction: Staff and patient Movement in static magnetic field MRI scanner induces current density in the human tissues, so cause biologic effects in people. The aim of this study was the Modelling of current density induced by moving individual with different velocities in static magnetic field of magnetic resonance imaging. Materials and Methods: current ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological measurement

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2017