Adenosine thallium-201 is superior to exercise thallium-201 for detecting coronary artery disease in patients with left bundle branch block.

نویسندگان

  • J H O'Keefe
  • T M Bateman
  • C S Barnhart
چکیده

OBJECTIVES We sought to assess the comparative diagnostic accuracy of adenosine versus exercise in conjunction with thallium-201 scintigraphy for the detection and localization of coronary artery disease in patients with left bundle branch block on the rest electrocardiogram (ECG). BACKGROUND Patients with left bundle branch block on the rest ECG frequently have artifactual reversible septal perfusion defects on exercise thallium-201 scintigraphy. Adenosine thallium scintigraphy is a theoretically attractive alternative in these patients. METHODS One hundred seventy-three consecutive patients with left bundle branch block were evaluated with either exercise thallium (n = 56) or adenosine thallium (n = 117) scintigraphy. The tomographic thallium images were interpreted visually with adjunctive quantitative analysis. Follow-up cardiac catheterization was performed in 31 of the 56 patients in the exercise thallium group and 42 of the 117 patients in the adenosine thallium group. RESULTS Minor subjective side effects were noted in most patients in the adenosine thallium group (86%); atrioventricular block occurred in seven patients (6%). The overall predictive accuracy was 93% in the adenosine thallium group and 68% in the exercise thallium group (p = 0.01). The combined specificity for the detection of disease in the coronary arteries subtending the septum (the left anterior descending and right coronary arteries) was only 42% with exercise thallium scintigraphy versus 82% with adenosine thallium scintigraphy (p < 0.0002). CONCLUSIONS Adenosine thallium imaging 1) was superior to exercise thallium imaging in the detection of coronary artery disease in patients with left bundle branch block; 2) obviated septal artifacts, thereby markedly improving the specificity in the left anterior descending and right coronary arteries; and 3) was safe in patients with left bundle branch block.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanism for abnormal thallium-201 myocardial scintigraphy in patients with left bundle branch block in the absence of angiographic coronary artery disease.

Patients with left bundle branch block (LBBB) often show abnormal images on exercise thallium (T1)-201 scintigraphy without evidence of significant coronary stenosis. We investigated the mechanism for this phenomenon. Six patients with LBBB and without significant coronary stenosis underwent T1-201 SPECT, ECG-gated SPECT imaging with Tc-99m-methoxyisobutyl-isonitrile (MIBI), and atrial pacing s...

متن کامل

Diagnosis of coronary artery disease by exercise thallium-201 tomography in patients with a right ventricular pacemaker.

OBJECTIVES We sought to study the accuracy of exercise perfusion scintigraphy in patients with an implanted apical right ventricular pacemaker. BACKGROUND The specificity of exercise perfusion scintigraphy is decreased in patients with a left bundle branch block. Patients with a permanent ventricular pacemaker have a similar conduction abnormality that may also potentially result in similar f...

متن کامل

Thallium-201 myocardial SPECT in a patient with mirror-image dextrocardia and left bundle branch block.

A 53-year-old male patient with a previous diagnosis of situs inversus with mirror-image dextrocardia underwent thallium-201 (Tl-201) stress-redistribution myocardial perfusion single photon emission computed tomography (SPECT). Electrocardiogram (ECG) obtained on right hemithorax revealed constant complete left bundle branch block. Tl-201 stress-redistribution SPECT images revealed abnormal pe...

متن کامل

Reproducibility of thallium-201 myocardial imaging.

Seventy-six thallium-201 myocardial perfusion studies were performed on twenty-five patients to assess their reproducibility and the effect ofvarying the level of exercise on the results of imaging. Each patient had a thallium-201 study at rest. Fourteen patients had studies on two occasions at maximum exercise, and twelve patients had studies both at light and at maximum exercise. Of 70 segmen...

متن کامل

Myocardial perfusion in patients with permanent ventricular pacing and normal coronary arteries.

OBJECTIVES The purposes of this study were to test the specificity of dipyridamole myocardial perfusion scintigraphy in patients with permanent ventricular pacing (PVP) and to evaluate coronary blood flow and reserve in these patients. BACKGROUND Permanent ventricular pacing is associated with exercise perfusion defects on myocardial scintigraphy in the absence of coronary artery disease (CAD...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 21 6  شماره 

صفحات  -

تاریخ انتشار 1993