Integrated Path Detection of Co2 and Ch4 Using a Waveform Driven Electro-optic Single Sideband Laser Source

نویسندگان

  • Gerd Wagner
  • Stephen Maxwell
  • David Plusquellic
چکیده

Integrated path concentrations of ambient levels of carbon dioxide and methane have been measured during nighttime periods at NIST, Boulder (CO, USA), using a ground-based, eyesafe laser system. In this contribution, we describe the transmitter and receiver system, demonstrate measurements of CO2 and CH4 in comparison with an in situ point sensor measurement using a commercial cavity ring-down instrument, and demonstrate a speckle noise reduction method.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

All‐fiber versatile laser frequency reference at 2 μm for CO2 space‐borne lidar applications

Sensing atmospheric gas traces is crucial for climate monitoring and to predict the importance of global climate changes. Among the various atmospheric constituents, carbon dioxide (CO2), methane (CH4) and water vapor (H2O-v), the most prominent greenhouse gasses, have a major impact on climate. Advanced monitoring techniques are necessary to measure these gas species on a global scale all arou...

متن کامل

Field detection of CO and CH4 by NIR 2f modulation laser spectroscopy

  A novel compact fiber-coupled NIR system based on a DFB diode laser source is employed as a portable and sensitive gas sensor for trace detection of combustion pollutant molecules. We demonstrate the performance of such an NIR gas sensor by tracing the absorption lines of CO and CH4 using 2f-WMS technique at moderate temperature of T ~ 600°C in the recuperator channel of an industrial furnace...

متن کامل

Short-Path Near-Infrared Laser Detection of Environmental Gases by Wavelength-Modulation Spectroscopy

The detection of environmental gases, 12CO2, 13CO2, and CH4, using near-infrared semiconductor lasers with a short laser path length is studied by means of wavelength-modulation spectroscopy. The developed system is compact and has high sensitivity enough to detect the absorption peaks of isotopic 13CO2 of a 3-% CO2 gas at 2 μm with a path length of 2.4 m, where its peak size is two orders of m...

متن کامل

Two-dimensional imaging of continuous-wave terahertz radiation using electro-optic detection

We report the demonstration of two-dimensional electro-optic imaging using continuous-wave THz radiation. Two single-frequency laser diodes serve as the optical source for both the generation and detection processes. The generation process occurs by mixing in a photoconductive emitter, while the detection process utilizes an electro-optic crystal and charge coupled device camera. The method per...

متن کامل

Demonstration of injection locking a diode laser using a ®ltered electro-optic modulator sideband

Many experiments in atomic physics require two laser beams with a controllable di€erence in frequencies. In this paper, we report on realizing this goal using a technique where an electro-optic modulator sideband is ®ltered through a cavity and injected into a diode laser, in a novel con®guration yielding very high feedback isolation without sacri®cing access to the output power of the diode la...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015