A 3-year multicentre randomized controlled trial of etonogestrel- and levonorgestrel-releasing contraceptive implants, with non-randomized matched copper-intrauterine device controls.
نویسندگان
چکیده
STUDY QUESTION Is there any difference in the clinical performance of the 3-year one-rod etonogestrel (ENG)- and the 5-year two-rod levonorgestrel (LNG)-releasing contraceptive implants during 3 years of insertion, and between implant and intrauterine device (IUD) contraception, in particular complaints possibly related to hormonal contraceptives? SUMMARY ANSWER The cumulative contraceptive effectiveness after 3 years and method continuation through 2.5 years were not significantly different between ENG and LNG implants, but both outcomes were significantly worse in the non-randomized age-matched group of IUD users than in the combined implant group. WHAT IS KNOWN ALREADY ENG- and LNG-releasing implants are safe and highly efficacious contraceptives with pregnancy rates reported to be 0.0-0.5 per 100 women-years (W-Y). No head-to-head comparative study of the two implants has been undertaken, and little information is available on comparisons of complaints of side effects of implant and copper IUD users. STUDY DESIGN, SIZE, DURATION This was an open parallel group RCT with 1:1 allocation ratio of the ENG and the LNG implants with non-randomized control group of women choosing TCu380A IUD to address lack of reliable data on common side effects typically attributed to the use of progestogen-only contraceptives. After device(s) placement, follow-ups were at 2 weeks, 3 and 6 months, and semi-annually thereafter for 3 years or until pregnancy, removal or expulsion of the implant/IUD occurred. PARTICIPANTS, SETTING, METHODS The study took place in family planning clinics in Brazil, Chile, Dominican Republic, Hungary, Thailand, Turkey and Zimbabwe. Women seeking long-term contraception were enlisted after an eligibility check and informed consent, and 2982 women were enrolled: 1003, 1005 and 974 in the ENG-implant, LNG-implant and IUD groups, respectively; 995, 997 and 971, respectively, were included in the per protocol analysis reported here. MAIN RESULTS AND THE ROLE OF CHANCE ENG and LNG implants each had the same 3-year cumulative pregnancy rate of 0.4 per 100 W-Y [95% confidence interval (CI) 0.1-1.4]. A weight of ≥70 kg at admission was unrelated to pregnancy. Method continuation rates for ENG and LNG implants at 2.5 years were 69.8 (95% CI 66.8-72.6) and 71.8 per 100 W-Y (68.8-74.5), and at 3 years 12.1 (95% CI 5.2-22.0) and 52.0 per 100 W-Y (95% CI 41.8-61.2), respectively. Bleeding disturbances, the most frequent reason for method discontinuation, were significantly more common in the ENG group [16.7 (95% CI 14.4-19.3)] than in the LNG group [12.5 (95% CI 10.5-14.9)] (P 0.019). The 3-year cumulative loss to follow-up was lower in the ENG- than in the LNG-implant group, 8.1 (95% CI 6.4-10.2) and 14.4 per 100 W-Y (95% CI 12.1-17.1), respectively. The median duration of implant removal was 50 s shorter among women with ENG than among women with LNG implant (P < 0.0001). In the observational comparison between IUD and implant users, the 3-year relative risk for pregnancy in IUD group compared with the combined implant group was 5.7 per 100 W-Y (95% CI 4.4-7.3) (P = 0.0003). The 3-year expulsion rate of the IUD was 17.8 per 100 W-Y (95% CI 14.5-21.9), while the discontinuation rate for bleeding disturbances was 8.5 (95% CI 6.7-10.9). Frequency of complaints of headache and dizziness was not significantly different between implant and IUD users (P = 0.16 and 0.77, respectively), acne and bleeding irregularities were more frequent among implant users (P < 0.0001), while heavy bleeding and lower abdominal pain occurred more often among IUD than implant users (P < 0.0001). LIMITATIONS, REASONS FOR CAUTION Few women were ≤19 years old or nulligravida, the proportion of implant users ≥70 kg was <20% and <8% were obese. WIDER IMPLICATIONS OF THE FINDINGS Findings of the study can inform policy makers and clinicians about choice of implant, but also about TCu380A IUD in relation to implants. STUDY FUNDING/COMPETING INTERESTS UNDP/UNFPA/WHO/UNICEF/World Bank Special Programme of Research, Development and Research Training in Human Reproduction (HRP), Department of Reproductive Health and Research (RHR), World Health Organization (WHO). This report contains the views of an international expert group and does not necessarily represent the decisions or the stated policy of the WHO. TRIAL REGISTRATION ISRCTN33378571 registered on 22 March 2004. The first participant was enrolled on 12 May 2003.
منابع مشابه
Extended Effectiveness of the Etonogestrel-Releasing Contraceptive Implant and the 20 µg Levonorgestrel-Releasing Intrauterine System for 2 Years Beyond U.S. Food and Drug Administration Product Labeling
BACKGROUND Contraceptive implants, the levonorgestrel-releasing intrauterine system (LNG IUS), and the copperbearing intrauterine device (IUD) are long-acting reversible contraceptives (LARCs) with high contraceptive effectiveness. The cumulative pregnancy rates in the first 3 years of use of LARCs is 0.9 per 100 woman-years. In comparison, the percentages of women experiencing an unintended pr...
متن کاملNon-contraceptive benefits of hormonal and intrauterine reversible contraceptive methods.
BACKGROUND Most contraceptive methods present benefits beyond contraception; however, despite a large body of evidence, many healthcare professionals (HCPs), users and potential users are unaware of those benefits. This review evaluates the evidence for non-contraceptive benefits of hormonal and non-hormonal contraceptive methods. METHODS We searched the medical publications in PubMed, POPLIN...
متن کاملEfficacy and Safety of Long-Acting Reversible Contraception in Women With Cardiovascular Conditions.
The physiological changes that occur during pregnancy can be deleterious to women with a cardiovascular condition. Evidence-based contraceptive counseling and provision is essential in this patient population. Although long-acting reversible contraception (LARCs), which include the intrauterine device (IUD) and the etonogestrel contraceptive implant, have been found to be safe and effective in ...
متن کاملExtended use up to 5 years of the etonogestrel-releasing subdermal contraceptive implant: comparison to levonorgestrel-releasing subdermal implant
STUDY QUESTION Is it possible to extend the use of the 3-year one-rod etonogestrel (ENG)-releasing subdermal contraceptive implant to 5 years? SUMMARY ANSWER The extended use of the one-rod ENG-releasing subdermal contraceptive implant showed 100% efficacy in years 4 and 5. WHAT IS KNOWN ALREADY The initial regulated trials on the ENG-releasing subdermal contraceptive implant conducted in t...
متن کاملProlonged intrauterine contraception: a seven-year randomized study of the levonorgestrel 20 mcg/day (LNg 20) and the Copper T380 Ag IUDS.
A levonorgestrel-releasing IUD and the Copper T 380Ag IUD were in randomized comparison for seven years in five clinics. In two other clinics the randomized study was truncated at five years, but use of the Copper T continued. No pregnancies occurred to users of either device in years 6 and 7. Cumulative pregnancy rates were 1.1 per 100 at seven years for the steroid-releasing and 1.4 per 100 f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Human reproduction
دوره 30 11 شماره
صفحات -
تاریخ انتشار 2015