Comparison of blood-flow velocity waveforms in different coronary artery bypass grafts. Sequential saphenous vein grafts and internal mammary artery grafts.

نویسندگان

  • T Fujiwara
  • F Kajiya
  • S Kanazawa
  • S Matsuoka
  • Y Wada
  • O Hiramatsu
  • M Kagiyama
  • Y Ogasawara
  • K Tsujioka
  • T Katsumura
چکیده

Characteristics of blood-flow velocities were investigated at different sites in two types of coronary artery bypass grafts, sequential saphenous vein grafts (SSVG) and internal mammary artery grafts (IMAG). The latter appear to have the longest life span. The patency rate of the side-to-side anastomosis of the SSVG is better than that of the end-to-side anastomosis. The SSVG was anastomosed to the major diagonal branch by side-to-side anastomosis and to the left anterior descending coronary artery (LAD) by end-to-side anastomosis in 13 patients who had 75-100% and 75-90% stenoses in the LAD and major diagonal branch, respectively. IMAG anastomoses were performed to the LAD in 10 patients with 75-100% stenoses of the artery. The blood-flow velocities were measured by the 20-MHz, eighty-channel ultrasound pulsed Doppler method during surgery. In six patients in the SSVG group, we investigated the configuration of velocity profiles at the region just proximal to the side-to-side anastomosis and at the bridge portion between the side-to-side and end-to-side anastomosis. In the other seven patients, we measured the blood-flow velocity at several centimeters proximal to the side-to-side anastomosis and compared it with that in the IMAG. At the region just proximal to the side-to-side anastomosis, the velocity profile skewed toward the anastomosis side wall in all patients, and the flow velocity near the wall opposite to the side-to-side anastomosis was reversed in five of six patients.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Remodeling leads to distinctly more intimal hyperplasia in coronary than in infrainguinal vein grafts.

BACKGROUND Flow patterns and shear forces in native coronary arteries are more protective against neointimal hyperplasia than those in femoral arteries. Yet, the caliber mismatch with their target arteries makes coronary artery bypass grafts more likely to encounter intimal hyperplasia than their infrainguinal counterparts due to the resultant slow flow velocity and decreased wall stress. To al...

متن کامل

Competitive flow and arterial graft a word of caution.

reliable, exclusively in appropriately selected situations. In creation of bypass grafts, durable completeness of revascularization and function of the ITA to the LAD bypass should not be compromised. We would suggest that the balanced bypass flow toward the LAD and the RCA is noticeably important to achieve an entire patency of the Y-graft for three-vessel regions. This study is not conclusive...

متن کامل

Intraoperative flow measurements in gastroepiploic grafts using pulsed Doppler.

OBJECTIVE The patency of a pedicled right gastroepiploic artery (RGEA) graft can be compromised by intraoperative twists, kinks or spasms. Therefore, a systematic flow assessment was made in RGEA grafts and was compared with similar measurements made in other types of bypass conduits. METHODS Intraoperative pulsed Doppler flowmeter measurements obtained in a series of 556 consecutive patients...

متن کامل

Adaptive mechanisms of arterial and venous coronary bypass grafts to an increase in flow demand.

OBJECTIVE To compare the mechanisms by which arterial and venous grafts increase their flow during pacing induced tachycardia, early and later after coronary bypass surgery. DESIGN 43 grafts (13 epigastric artery, 15 mammary artery, 15 saphenous vein) evaluated early (9 (3) days (mean (SD)) after bypass surgery were compared with 41 other grafts (15 epigastric, 11 mammary, 15 saphenous vein) ...

متن کامل

Different Coronary Artery Bypass Grafts Sequential Saphenous Vein Grafts and Internal Mammary Artery Grafts

Characteristics of blood-flow velocities were investigated at different sites in two types of coronary artery bypass grafts, sequential saphenous vein grafts (SSVG) and internal mammary artery grafts (IMAG). The latter appear to have the longest life span. The patency rate of the side-to-side anastomosis of the SSVG is better than that of the end-to-side anastomosis. The SSVG was anastomosed to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 78 5 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1988