Importance of blood-collection tubes in plasma lidocaine determinations.
نویسندگان
چکیده
In 25 clinical samples serum lidocaine concentrations fell from a mean of 6.5 +/- 2.1 mg/L (mean +/- SD) to 4.9 +/- 1.8 mg/L (p less than 0.001) when the blood sample was allowed to make contact with the stopper of the Vacutainer collection tube. In vitro experiments showed that this effect of the stopper occurred only with whole blood and was dependent on sample concentration. The plasma binding of lidocaine decreased from a normal value of 56% +/- 2.2 (mean +/- SD) to 28% +/- 2.2 (p less than 0.001) when exposed to the Vacutainer stopper. We conclude that a chemical leached from such stoppers displaces lidocaine from its plasma-binding sites and that the drug is then redistributed into the erythrocytes, producing spuriously low lidocaine concentrations in plasma or serum. Such artifacts are important in therapeutic drug monitoring and can lead to erroneous clinical decisions.
منابع مشابه
Comparison of glucose determinations on blood samples collected in three types of tubes.
Because of the metabolism of serum glucose in collection tubes containing blood samples, serum glucose levels may be found to decrease over time. Several types of collection tubes have been designed to, at least partially, block glucose metabolism by red blood cells in blood collection tubes that may not be analyzed immediately after blood collection. These include red-top collection tubes with...
متن کاملInterleukin-1/3 in Human Plasma: Optimization of Blood Collection, Plasma Extraction, and Radioimmunoassay Methods
Current immunoassays for interleukin-lp (IL-lp) are effective for analyzing fluids derived from cultured cells. However, IL-1|3 determinations in human plasma or serum samples are technically complicated by higher protein and lipid concentrations, physicochemical differences which exist between samples from healthy subjects and those experiencing acute phase responses, and by the fact that IL-1...
متن کاملSpecial collection and storage tubes for blood endotoxin and cytokine measurements.
Commercially available blood-collection tubes may be contaminated with endotoxin (315 +/- 95 pg/tube) and could therefore be unsuitable for blood collection for endotoxin measurement. Plasma separation and storage are a potential source of contamination. To avoid contamination and error, we have developed new blood collection tubes that contain heparin free of endotoxin (LPS) and a gel to separ...
متن کاملPerformance Comparison of Two Different Branded Blood Collection Tubes Used in Biochemistry Laboratory
Background and Aims: Blood collection tubes (BCT) with gel separators are diagnostic devices that can affect all laboratory processes. In this study, the aim was to compare the performance of a new brand of BCT with the sample tubes that are well-known and widely used in the market. Materials and Methods: Blood samples were taken from 50 healthy volunteers to two brands of BCTs (KWS and BD Vac...
متن کاملClotting time analysis of citrated blood samples is strongly affected by the tube used for blood sampling.
Our aim was to establish whether differences in clotting times for recalcified blood and plasma samples might be explained by the use of different blood collection tubes. Samples obtained from different plastic vacuum tubes were recalcified and clotting times determined by free oscillation rheometry. The clotting times for blood collected in Vacutainer (Becton Dickinson, Rutherford, New Jersey,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 25 4 شماره
صفحات -
تاریخ انتشار 1979