AquaLite bioluminescence assay of thyrotropin in serum evaluated.

نویسندگان

  • D S Sgoutas
  • T E Tuten
  • A A Verras
  • A Love
  • E G Barton
چکیده

We studied a new commercially available thyrotropin (TSH) assay, the AquaLite Bioluminescence TSH-Immunoassay (SeaLite Inc.). This assay has a detection limit of 0.005 mIU/L and a functional sensitivity of 0.017 mIU/L and meets the requirements of a third-generation TSH assay. Using this assay, we measured serum TSH in 153 euthyroid individuals and in the following patients: 32 primary hypothyroids; 38 primary hyperthyroids; 35 with thyroid cancer receiving suppressive therapy with levothyroxine (L-T4); 33 receiving replacement L-T4 aimed at reaching and maintaining a euthyroid status; 23 with subclinical hyperthyroidism; and 52 hospitalized for nonthyroidal illnesses (NTI). The AquaLite TSH assay perfectly discriminated hypothyroid and untreated hyperthyroid patients from euthyroid subjects and clearly discriminated between overtly and mildly hyperthyroid patients. Intermethod comparisons showed that the AquaLite and the Nichols assays were more effective than the ACS-180 and the TOSOH assays in discriminating among hyperthyroid patients, including patients over-treated with L-T4.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A bioluminescence assay for thyrotropin receptor antibodies predicts serum thyroid hormone levels in patients with de novo Graves' disease.

BACKGROUND TSH receptor antibodies (TBII) in Graves' disease (GD) may be TSH receptor stimulating (TSAb) and blocking (TBAb) antibodies. In commercially available assays however, only total TBII titres can be measured, without discriminating between TSAb and TBAb. OBJECTIVE To design a TBII bioassay to detect of TSAb and to correlate TSAb activity with severity of hyperthyroidism in de novo G...

متن کامل

A thyrotropin radioimmunoassay kit evaluated vs two reference assays.

We evaluated a double-antibody radioimmunoassay kit for thyrotropin that includes calibrators prepared in a matrix of human serum and involves overnight nonequilibrium. Results were compared with those from two reference assays for thyrotropin. The range of within-assay CVs for the kit for thyrotropin values between 0.9 and 2.4 milli-int. units/L was 2.2 to 5.3%, that for between-assay CVs was ...

متن کامل

Bioluminescence measurement of primary bile acids using immobilized 7 alpha-hydroxysteroid dehydrogenase: application to serum bile acids.

A simple, rapid, and sensitive bioluminescence method for measuring primary bile acids has been developed and validated. The method is based on enzymatic dehydrogenation of bile acids using a bacterial 7 alpha-hydroxysteroid dehydrogenase that is co-immobilized on Sepharose 4B beads with NADH:FMN oxidoreductase and a bacterial luciferase. The assay is specific for 7 alpha-hydroxy bile acids and...

متن کامل

SERUM LEVELS OF PROLACTIN, THYROTROPIN. THYROID HORMONES, TRH RESPONSIVENESS, AND MALE REPRODUCTIVE FUNCTION IN INTERMITTENT ISLAMIC FASTING

During the Islamic lunar month of Ramadan millions of Muslims abstain from drinking and eating from dawn to sunset. The objective of this study was to investigate the effect of intermittent Islamic fasting on reproductive function, hypothalamic-pituitary-thyroid axis and the peripheral metabolism of thyroid hormones in men. We measured serum levels of FSH. LH, testosterone, prolactin, FSH, T4...

متن کامل

Immunoradiometric assay of thyrotropin as a "first-line" thyroid-function test in the routine laboratory.

We compared the utility of a sensitive immunoradiometric assay for serum thyrotropin as a "first-line" thyroid-function test with a strategy based on first measuring total thyroxin in serum. The immunoradiometric assay appears to distinguish primary hypothyroidism and hyperthyroidism from euthyroidism in "new" patients. The role of this test in monitoring antithyroid treatment or thyroxin-repla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 41 11  شماره 

صفحات  -

تاریخ انتشار 1995