Molecular Sieve Sensors for Selective Detection at the Nanogram Level
نویسندگان
چکیده
Acknowledgment. This research was supported by PHS Grant CA28824. N M R spectra were obtained through the auspices of the Northeast Regional NSF/NMR Facility at Yale University, which was supported by N S F Chemistry Division Grant C H E 7916210. An N.I.H. Postdoctoral Fellowship to J.N.H. (Grant 1 F32 CA08341-02) is gratefully acknowledged. In addition, we thank Dr. Nathan B. Mantlo of Merck Sharp & Dohme Research Laboratories, Rahway, N J for helpful discussions.
منابع مشابه
Application of Zeotype SAPO-34 Molecular Sieve as a Selective Adsorbent for Separation of Ethylene from Ethane
The process of ethylene production from ethane dehydrogenation is one of the interesting processes in the field of conversion the petroleum light gases to the valuable products. In this process, the outlet gaseous product is a combination of ethylene, ethane and hydrogen. Effective separation techniques are required for separation of ethylene from unreacted ethane. Here a new adsorbent approach...
متن کاملOrtho-phenylenediamine Based Bis-ureas as the Ion Selective Sensors; A QM/MD Study
Density functional theory dispersion corrected (DFT-D3)calculations and molecular dynamic (MD) simulation were applied to investigate the sensing ability of four types of receptors (RCs) composed of the ortho-phenylenediamine based bis-ureas for selective complexation with the anions such as Cl–, Br–, OAC–, PhCO2–, H2PO4– and HSO4– in the gas phase and DMSO. On the basis of the data obtained fr...
متن کاملIon Selective Carbon Paste Electrode For The Determination Of Flavoxate Muscle Relaxant Drug In Pharmaceutical Formulation
Abstract The utility of carbon paste electrode for the determination of flavoxate HCl modified with flavoxate-tetraphenylborate (FLX-TPB) and flavoxate-phosphotungestic acid (FLX-PTA) ion-pairs in batch mode is demonstrated. The electrodes revealed a Nernstian response over a wide concentration ranges 1.39×10-5-1x10-2 mol L-1 and1×10-5-1x10-2 mol L-1 using FLX-TPB and FLX-PTA, respectively. The...
متن کاملNanobiosensor designing with molecular framework polymer method compared with agent-linked nanosilica biosensor for Staphylococcus aureus exotoxin detection
Considering the ever increasing population and industrialization leading to developmental trend of humankind's life, we are hardly able to detect the toxins produced in food products using traditional techniques. In this technique, the production of molecular framework and polymer is done using meta acrylic acid monomers, which are formed via covalence connection between meta acrylic acid monom...
متن کاملAnalysis of the Sensitivity of K-Type Molecular Sieve-Deposited MWNTs for the Detection of SF6 Decomposition Gases under Partial Discharge
Sulfur hexafluoride (SF6) is widely utilized in gas-insulated switchgear (GIS). However, part of SF6 decomposes into different components under partial discharge (PD) conditions. Previous research has shown that the gas responses of intrinsic and 4 Å-type molecular sieve-deposited multi-wall carbon nanotubes (MWNTs) to SOF2 and SO2F2, two important decomposition components of SF6, are not obvio...
متن کامل