Importance of personal dose equivalent evaluation in Fukushima in overcoming social panic.
نویسندگان
چکیده
The relationship between the reported ambient dose equivalent (H*(10)) and the individual dose rate recorded by medical staff in Fukushima City after the accident at the Fukushima Daiichi nuclear power plant was evaluated, following a 9.0-magnitude earthquake that struck the east coast of Japan. Personal dose equivalent (H(p)(10)) ranged from 0.08 to 1.63 µSv h(-1) and H*(10) ranged from 0.86 to 12.34 µSv h(-1). H(p)(10) from March to July 2011 were significantly lower than H*(10). The relationships between these dose equivalents were moderately correlated. The regression equation was calculated as follows: H(p)(10)=0.0696×H*(10)+0.0538. The preliminary data of this study show that, in Fukushima, the individual dose is much lower than that determined H*(10). It is important to evaluate H(p)(10) in order to lessen the anxiety of the general population in Fukushima.
منابع مشابه
Evaluation of personal dose equivalent using optically stimulated luminescent dosemeters in Marumori after the Fukushima nuclear accident.
The personal dose equivalent for 36 Marumori residents living in wooden houses was evaluated using optically stimulated luminescent dosemeters after the Fukushima nuclear accident. The cumulative doses to residents over 200 d from 1 September 2011 ranged from 536 to 1490 µSv. In each resident's house, the indoor and outdoor ambient dose equivalents were measured with an NaI scintillation survey...
متن کاملCalculation of airkerma conversion factor to personal dose equivalent at various depths using the Monte Carlo Code GATE
Several studies have been done with the aim of improving the quality of the radiation protection measurement in radiology and nuclear medicine. Among different subjects which are capable to be considered in this area, the measurement of the operational quantities of protection against the radiation ,such as, personal dose equivalent ,HP(d), at different depths (d=0.07mm, 3mm, 10mm) is an impor...
متن کاملActive Personal Dosimeter in a Nuclear Medicine Center in Yazd City, Iran
Introduction: Active personal dosimeters (APDs) are well accepted as useful and reliable instruments for individual dosimetry measurements. APDs have many advantages compared with passive dosimeters for individual external radiation dose assessments. In routine monitoring, occupational exposure is carried out for verification and demonstration of compliance with the regulatory dose limits. So, ...
متن کاملAn evaluation of the equivalent dose due to natural radioactivity in the soil around the consolidated Tin mine in Baukuru-Jos, plateau state of Nigeria
Background: The equivalent dose in the human body due to the natural gamma-emitting radionucides (238U, 232Th and 40K) in the surface soil surrounding the Consolidated Tin mine site in Bukuru-Jos, Nigeria has been determined in this study. Materials and Methods: Measurements of the soil natural radioactivity were made using a multi-channel pulseheight analyzer (Canberra Series 10 plus) coupled ...
متن کاملPredicting social well-being based on health-oriented lifestyle and irrational beliefs in women with panic disorder
Background and Aim: Panic disorder is one of the anxiety disorders caused by frequent and sudden attacks of fear and anxiety, and its sufferers experience a decline in health and well-being. Therefore, the aim of the present study was to predict social well-being based on health-oriented lifestyle and irrational beliefs in women with panic disorder. Methods: This descriptive research was corre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiation protection dosimetry
دوره 151 1 شماره
صفحات -
تاریخ انتشار 2012