Low-Dose Scanning Technology Combined with Low-Concentration Contrast Material in Renal Computed Tomography Angiography (CTA): A Preliminary Study
نویسندگان
چکیده
BACKGROUND This study is to investigate the feasibility of low iodine concentration contrast material (CM) combined with low tube voltage and adaptive statistical iterative reconstruction (ASIR) in renal computed tomography angiography (CTA). MATERIAL AND METHODS A total of 136 patients were enrolled in this prospective trial, and randomly divided into two groups: group A (n=68) and group B (n=68). Group A received 120-kVp and iopromide (370 mg/mL) with filtered back projection (FBP) reconstruction, and group B received 100-kVp and iodixanol (270 mg/mL) with ASIR 40% (ASIR40). An equal iodine dose (300 mg/kg body weight) and the same iodine delivery rate (1,500 mg I/s) were given to all patients. Density, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured, and the image quality and visualization of renal arteries were scored. Dose-length product (DLP) and CT dose index volume (CTDIvol) were recorded, and effective doses (ED) were calculated. RESULTS There was no significant difference in image noise between groups A and B (p>0.05). The vessel attenuation, SNR, and CNR were significantly higher in group B than group A (all p<0.05). The subjective image quality and visualization of renal artery branches were similar in these two groups (p>0.05). Compared with group A, the CTDIvol, DLP, and ED in group B were decreased by 38.58%, 37.24%, and 37.24%, respectively (p=0.000). CONCLUSIONS Compared with 120-kVp with FBP reconstruction, the protocol of 100-kVp with ASIRP40 reconstruction provided high-quality renal CTA results, which allowed for reduced iodine concentration and decreased radiation dose.
منابع مشابه
Clinical applications of virtual, non-contrast head images derived from dual-source, dual-energy cerebrovascular computed tomography angiography
Background: This study set out to evaluate the utility of cerebrovascular virtual non-contrast (VNC) scans. Materials and Methods: Conventional non-contrast (CNC) and dual-energy computed tomography angiography (DE-CTA) head scans were conducted on 100 subjects, of which 46 were normal, 15 had parenchymal hematomas of the brain, 13 had ischemic infarction, 22 had tumors, and 4 had calcified les...
متن کاملLow kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose
Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...
متن کاملAssessment of radiation-induced cancer risk to patients undergoing computed tomography angiography scans
Background: Computed tomography angiography (CTA) scan is a suitable imaging technique to evaluate the blood vessels. However, one major disadvantage is the potential risk of cancer related to ionizing radiation exposure during the procedures. The aim of this investigation was to estimate the risk of exposure induced cancer death (REID) values for some common computed tomography angiography (CT...
متن کاملCT Angiography of the Head-and-Neck Vessels Acquired with Low Tube Voltage, Low Iodine, and Iterative Image Reconstruction: Clinical Evaluation of Radiation Dose and Image Quality
OBJECTIVES We aimed to assess the effectiveness and feasibility of head-and-neck Computed Tomography Angiography (CTA) with low tube voltage and low concentration contrast media combined with iterative reconstruction algorithm. METHODS 92 patients were randomly divided into group A and B: patients in group A received a conventional scan with 120 kVp and contrast media of 320 mgI/ml. Patients ...
متن کاملImaging Quality Evaluation of Low Tube Voltage Coronary CT Angiography Using Low Concentration Contrast Medium
PURPOSE To compare the image quality of prospectively ECG-gated low voltage coronary computed tomography angiography (CTA) with an administration of low concentration contrast medium. METHOD AND MATERIALS A total of 101 patients, each with a heart rate below 65 beats per minute (BPM), underwent a prospectively ECG-gated axial scan in CT coronary angiography on a 64-slice CT scanner. All patie...
متن کامل