Interferometry and laser control with solid Fabry-Perot etalons.
نویسندگان
چکیده
The use and analysis of solid Fabry-Perot etalons for interferometry and laser control are discussed and supported with experimental data. Low angle scattering is found to be an important factor influencing finesse and peak transmission. Thermal tuning sensitivity and wedge-angle control with thermal gradients are analyzed and illustrated. Control of laser oscillations using a solid-state etalon as a laser cavity end mirror is discussed. The use of the solid etalon as an optical cavity coupler is applied to the problem. of sideband energy removal from an internally modulated laser.
منابع مشابه
Micromachined three-dimensional tunable Fabry-Perot etalons
We report on novel three-dimensional tunable Fabry-Perot etalons fabricated by surface micromachining technique. The Fabry-Perot etalons are tuned by rotation or translation movements. For the Fabry-Perot etalon tuned by rotational movement, the Fabry-Perot etalon is integrated with a rotational stage and the effective light path distance is adjusted by rotating the stage. The transmission peak...
متن کاملHigh-accuracy Fabry–Perot displacement interferometry using fiber lasers
We describe ongoing work in a Fabry–Perot interferometry system designed to measure displacements over a range of 50 mm with sub-pm uncertainty. The apparatus involves probing two nearby modes of the Fabry–Perot cavity with narrow-linewidth fiber telecom lasers and measuring both the mode spacing and the absolute mode frequencies relative to a third, frequency-stabilized, fiber laser. We explor...
متن کاملNovel Optical Design of Folded Fabry-perot Displacement Measurement Interferometer
Due to its high resolution and the large measuring range, laser interferometer has been applied widely to the precision industrial measurement and calibration. Fabry-Perot interferometry was often used for the microdisplacement, because of its common optical path structure being insensitive to the environmental disturbances. In the past researches, some kinds of modified Fabry-Perot interferome...
متن کاملIntra-Tissue Pressure Measurement in Ex Vivo Liver Undergoing Laser Ablation with Fiber-Optic Fabry-Perot Probe
We report the first-ever intra-tissue pressure measurement performed during 1064 nm laser ablation (LA) of an ex vivo porcine liver. Pressure detection has been performed with a biocompatible, all-glass, temperature-insensitive Extrinsic Fabry-Perot Interferometry (EFPI) miniature probe; the proposed methodology mimics in-vivo treatment. Four experiments have been performed, positioning the pro...
متن کاملDisplacement Interferometry Win Passive Fabry-perot Cavity
We present techniques oriented to improvement of precision in incremental interferometric measurements of displacements over a limited range where the atmospheric wavelength of the coherent laser source is either directly stabilized to a mechanical reference or is corrected to fit to the reference. This may represent a reduction of uncertainty linking the laser wavelength not to indirectly eval...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 5 6 شماره
صفحات -
تاریخ انتشار 1966