Experience with Magnetic Shielding of a Large Scale Accelerator

نویسندگان

  • S. Nagaitsev
  • C. Gattuso
چکیده

It is not unusual to place multiple accelerators in a common enclosure to save on civil construction costs. This often complicates operations, especially if accelerators are affecting each other. At Fermilab, the influence of a rapidly cycling Main Injector (MI) synchrotron on an antiproton storage ring (Recycler), placed in a common tunnel, was initially found to be unacceptable for a reliable operation of the Recycler. Initial closed orbit excursions in the Recycler ring during the MI ramp were in excess of 5 mm (rms). This paper describes a shielding technique, used to reduce these orbit excursions by a factor of five.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shielding simulations for safe use of curtain electron accelerator by MCNP4C

In an electron curtain accelerator, when the electron beam passes through the titanium exit window of the accelerator chamber, X-ray photons are produced as a negative by-product of retarding accelerated electrons. Controlling the produced X-ray photons to avoid their detrimental effects or in fact, proper shielding of the accelerator is an important issue that has to be considered in the use o...

متن کامل

Application of High Temperature Superconductors to Accelerators

Since the discovery of high temperature superconductivity, a large effort has been made by the scientific community to investigate this field towards a possible application of the new oxide superconductors to different devices like SMES, magnetic bearings, flywheels energy storage, magnetic shielding, transmission cables, fault current limiters, etc. However, all present day large scale applica...

متن کامل

Large-scale Inversion of Magnetic Data Using Golub-Kahan Bidiagonalization with Truncated Generalized Cross Validation for Regularization Parameter Estimation

In this paper a fast method for large-scale sparse inversion of magnetic data is considered. The L1-norm stabilizer is used to generate models with sharp and distinct interfaces. To deal with the non-linearity introduced by the L1-norm, a model-space iteratively reweighted least squares algorithm is used. The original model matrix is factorized using the Golub-Kahan bidiagonalization that proje...

متن کامل

Magnetic decoupling of the linac in a low field biplanar linac-MR system.

PURPOSE The integration of a low field biplanar magnetic resonance (MR) imager and linear accelerator (linac) causes magnetic interference at the linac due to the MR fringe fields. In order to eliminate this interference, passive and active magnetic shielding designs are investigated. METHODS The optimized design of passive magnetic shielding was performed using the finite element method. The...

متن کامل

Protective and dosimeter design of the stationary and mobile model truck inspection system with electron linear accelerator radiation source

In this work, calculations of leaked dose from vehicle inspection area, the absorbed dose by driver and operator, and the required concrete thickness for shielding the inspection area are presented using the Monte Carlo code MCNPX2.6. The X-ray source of the present vehicle inspection system is a LinatronMi6 accelerator, end of which has only been simulated in this study (the electron beam coll...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001