Minimally invasive method of determining blood input function from PET images in rodents.

نویسندگان

  • Joonyoung Kim
  • Pilar Herrero
  • Terry Sharp
  • Richard Laforest
  • Douglas J Rowland
  • Yuan-Chuan Tai
  • Jason S Lewis
  • Michael J Welch
چکیده

UNLABELLED For cardiovascular research on rodents, small-animal PET has limitations because of the inherent spatial resolution of the system and because of cardiac motion. A factor analysis (FA) technique for extracting the blood input function and myocardial time-activity curve from dynamic small-animal PET images of the rodent heart has been implemented to overcome these limitations. METHODS Six Sprague-Dawley rats and 6 BALB/c mice underwent dynamic imaging with 18F-FDG (n = 6) and 1-11C-acetate (n = 6). From the dynamic images, blood input functions and myocardial time-activity curves were extracted by the FA method. The accuracy of input functions derived by the FA method was compared with that of input functions determined from serial blood samples, and the correlation coefficients were calculated. RESULTS Factor images (right ventricle, left ventricle, and myocardium) were successfully extracted for both 18F-FDG and 1-11C-acetate in rats. The correlation coefficients for the input functions were 0.973 for 18F-FDG and 0.965 for 1-11C-acetate. In mice, the correlation coefficients for the input functions were 0.930 for 18F-FDG and 0.972 for 1-11C-acetate. CONCLUSION The FA method enables minimally invasive extraction of accurate input functions and myocardial time-activity curves from dynamic microPET images of rodents without the need to draw regions of interest and without the possible complications of surgery and repeated blood sampling.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image-derived input function from the vena cava for 18F-FDG PET studies in rats and mice.

UNLABELLED Measurement of arterial input function is a restrictive aspect for quantitative (18)F-FDG PET studies in rodents because of their small total blood volume and the related difficulties in withdrawing blood. METHODS In the present study, we took advantage of the high spatial resolution of a recent dedicated small-animal scanner to extract the input function from the (18)F-FDG PET ima...

متن کامل

Simplified nonlinearity correction of oxygen-15-water regional cerebral blood flow images without blood sampling.

UNLABELLED A noninvasive method, the double-integration method, was developed to estimate regional cerebral blood flow (rCBF) by using 15O-water and PET. It relies on the acquisition of images with a correction of nonlinearity of brain tissue counts and can produce rCBF images on a pixel-by-pixel basis. METHODS Oxygen-15-water PET studies were performed on five normal human volunteers, and co...

متن کامل

Noninvasive quantitation of cerebral blood flow using oxygen-15-water and a dual-PET system.

UNLABELLED Measurement of the arterial input function is essential for quantitative assessment of physiological function in vivo using PET. However, frequent arterial blood sampling is invasive and labor intensive. Recently, a PET system has been developed that consists of two independent PET tomographs for simultaneously scanning the brain and heart, which should avoid the need for arterial bl...

متن کامل

Improved Imaged-derived Input Function for Study of Human Brain FDG-PET

A reliable, semi-automated method for estimation of a minimally-invasive image-derived input function is validated for human [F]-fluoro deoxyglucose (FDG) positron emission tomography (PET) studies. Two time windows can be recognized in the time activity curve measured from a carotid artery region of interest (CA-ROI). During the first short window of very rapid change, the dominant contaminati...

متن کامل

Noninvasive Extraction of Input Function from Carotid Artery in H2 O Dynamic Brain Positron Emission Tomography Using Independent Component Analysis

For the absolute quantification of regional cerebral blood flow (rCBF) by means of H2 15 O positron emission tomography (PET) and kinetic modeling, arterial input function should be determined accurately. Even if arterial blood sampling, as an input function, provides an accurate time-activity curve (TAC), it is invasive and delay from carotid artery to radial artery should be corrected. Since ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 47 2  شماره 

صفحات  -

تاریخ انتشار 2006